05.91
4.5
Rapid traverse override expansion key group
RAPID TRAVERSE OVERRIDE
The position of the rapid traverse override switch is indicated in the RAPID TRAVERSE OVER-
RIDE signals by the following code:
Position
Code
Override value
C
B
A
1
0
0
1
2
0
1
1
3
0
1
0
4
1
1
0
5
1
1
1
6
1
0
1
7
1
0
0
Notes:
•
The percentage values given in the table are standard values which are stored as machine
data. They can be changed if required.
•
The rapid traverse override switch codes can be transferred unchanged from input byte
m + 4 to the PLC/NC interface.
•
Rapid traverse override replaces the axis selection switch in the rapid traverse override
key group. The other operator controls are deleted.
© Siemens AG 1991 All Rights Reserved
SINUMERIK 880 (PJ)
in %
1
10
50
100
6ZB5 410-0HE02
4 Description of Machine Control Panel Signals
4.5 Rapid traverse override expansion key group
IB m+4, bit 0 to 2
4–15