(3) Send data
Device
(S3)+0
(S3)+1
to
(S3)+n
(4) Functions
• This instruction sends the data specified by (S3) to the connected device of the connection specified by (S1)
for the module specified by Un.
CPU module
(S3)
Send data length
Send data
Send data
166
Item
Specify send data length. (Depending on the procedure of
fixed buffer communications, the data length is the
number of words or the number of bytes.)
Procedure exists (communications using a binary
Send data
code): Number of words
length
Procedure exists (communications using an ASCII
code): Number of words
No procedure (communications using a binary code):
Number of bytes
Send data
Specify the send data.
BUFSND
:
:
Setting data
E71
Fixed buffer data area
No.1
:
No.n
:
No.16
Setting range
Set by
-
1 to 1017
User
1 to 508
1 to 2046
-
User
Connected device