Automatic Cycle In Containers; Vacuum Packing In Magic Vac ® Executive Containers Or With; Magic Vac ® Universal Caps - Magic Vac Jumbo Operating Manual

Vacuum packing professional machine
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22

8 - Automatic cycle in containers

Executive containers, in containers sealed with MAGIC VAC
For creating a vacuum in MAGIC VAC
Universal Caps, in
®
®
bottles using MAGIC VAC
bottle caps and in glass jars with lid and ring.
®
8.1 - Vacuum packing in MAGIC VAC
Executive containers or in containers sealed with MAGIC VAC
®
®
Universal Caps
WARNING:
Use only and exclusively MAGIC VAC
Executive containers since they resist the vacuum value created by Jumbo,
®
whereas other types of containers could implode under the vacuum pressure of the appliance and cause injury.
The MAGIC VAC
Executive containers and the MAGIC VAC
Universal
®
®
Caps with star-shaped knob (fig. P) make vacuum packing easier,
because the connection hose can be introduced directly into the knob
central hole (fig. Q).
MAGIC VAC
Universal Caps, available in two diameters (100 mm and
®
125 mm), are to be used on jars for preserving food and bowls and
receptacles made of tempered glass. The Universal Caps work just
like the Caps for MAGIC VAC
Executive containers.
®
P
WARNING: With MAGIC VAC
Universal Lids do not use plastic or glass containers that are not suitable for vacuum
®
since they could implode under the vacuum pressure of the appliance and cause injury.
a) Fill the container, leaving at least 3 cm of room from the upper rim of
(16)
the container and position the cap on the container. Turn the knob to
(4)
the "VACUUM" position. (fig. P)
b) Connect the container cap knob to the appliance air inlet (4) by
means of the connection hose (16) (fig. Q)
N.B.: at the beginning of the vacuum phase it may be necessary to
press down the container cap with your hand to seal the container
Q
c) Press the "C" button (2G); the appliance will automatically carry out
a vacuum packing cycle and turn off on its completion.
In any case the pump switches off automatically after about 5 minutes.
d) Disconnect the tube from both the container lid knob and the
(2A) (2B)
(2D)
(2E)
(2F) (2G)
(2H)
(2C)
(3)
(4)
appliance air inlet.
e) Turn the knob to the "CLOSED" position.
To open the containers turn the knob to the "OPEN" position, you should hear a hissing of air as it enters the container.
This sound guarantees that the contents have been packed in a vacuum.
29

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Jumbo and is the answer not in the manual?

Table of Contents