The remaining thread monitor (MP 1, Optionale Einrichtungen (Optional
equipment)) and the bobbin counter (MP 6) can be activated simultane-
ously. The display shows the two options as follows:
Fig. 47: Remaining thread monitor and bobbin counter
(1) - Display - remaining thread monitor:
70
Remaining thread monitor active:
R shown
Remaining thread monitor inactive:
R hidden
MP2 - Limit values
Symbol
Meaning
Max. speed
(min. = 500 .. max. = 2700; Def. 2700 rpm)
All sewing programs are limited to this maximum speed.
Max. run-empty speed
(min. = 10 .. max. = 100; Def. 100 %)
Limits all clamp movements between the seams to this value.
Feed starting angle
(min. = 30 .. max. = 350; Def. 210 degrees)
The clamp motion during the stitch starts at this angle of needle motion.
Feed phase
(min. = 30 .. max. 100; Def. 80 %)
This parameter defines how the clamp is to be moved during the stitch.
(A value of 100 % means that the desired clamp motion is distributed over
the entire stitch.)
Needle reversing position
(min. = 0 .. max. 359; Def. 0 degrees)
The needle is reversed at this angle in order to increase the clearance to
the clamp.
Edit time paths
This function is only for Dürkopp Adler Service personnel.
(2) - Display - bobbin counter:
Bobbin counter active: Number black
Bobbin counter inactive:
Number grayed-out