Code
Machine control
3100
3102
3103
3107
3109
3121
3123
3210
3215
3220
3500
3501
3502
3721
3722
4201
5301
6551
6554
6651
6653
6751
6761
6952
Operating Instructions 911-210 - 04.0 - 11/2016
Description
Machine control voltage
• Temporary line voltage interruption
Machine voltage in sewing motor
intermediate circuit
• Temporary line voltage interruption
Machine voltage in stepper motor
intermediate circuit
• Temporary line voltage interruption
Machine temperature
• Ventilation openings closed
• Ventilation grille dirty
Threading mode is switched on
Compressed air is missing or
insufficient
Oil sensor active
Thread broken
Bobbin empty (remaining thread
counter)
Bobbin empty (remaining thread
counter)
Error in calculating the contour data
Target position of the XY clamps
outside the motion limits
Target position of the XY clamps
within the "forbidden areas"
Internal error
Internal CF card defective
Program cannot be sewn
Error in machine head position/AD
converter/process error
Internal error
Stepper motor driver error
Internal error
Troubleshooting
• Check the line voltage
• Check the line voltage
• Check the line voltage
• Clean ventilation grille
• Check ventilation openings
Switching off threading mode
Turn on the compressed air, stabilize
Top off oil
Re-thread the thread
Insert full bobbin
Insert full bobbin
• Reload the contour data
• Check the contour data
Adjust the contour data
Adjust the contour data
• Switch off and on the machine
• Software update
• Notify DA Service
• Switch off and on the machine
• Retrofit/replace control
Copy program to DAC
• Switch off and on the machine
• Software update
• Notify DA Service
• Switch off and on the machine
• Software update
• Notify DA Service
119