DURKOPP ADLER 911-210 Operating Instructions Manual page 70

Hide thumbs Also See for 911-210:
Table of Contents

Advertisement

3. Tap the desired parameter.
 The window for modifying the parameter value opens.
4. Set the parameter to the desired value ( p. 40).
There are 6 machine parameter groups:
Overview of the individual machine parameters
68
Symbol
Parameter group
MP1 - Configuration
General settings
MP2 - Limit values
Limit values for speeds and positions
MP3 - Needle thread monitor
Behavior after thread breakage
MP4 - Thread cutting
Speed, position and tension
MP5 - Thread clamping
Starting angle
MP6 - Counters
Settings for program and bobbin counters
MP1 - Configuration
Symbol
Meaning
Needle cooling
The following options can be set:
None: No type of needle cooling is active.
Air cooling (Def.): The needle is cooled with air while sewing the seam.
Ice cooling: Optional equipment.
Foot mode
The foot can be operated in the following modes:
Hopper: The foot only presses on the sewing material while the needle is
in the sewing material.
Presser: The foot presses continuously on the sewing material.
Sewing field size
Take care to ensure a valid sewing field size for your subclass when
making the selection! (See chapter Technical data ( p. 121))
Normal sewing field (Def.): A sewing field of up to 200 x 300 mm is
available.
Extra-large sewing field: A larger sewing field can be used in conjunction
with the alternating clamps.
Programming
Operating Instructions 911-210 - 04.0 - 11/2016

Advertisement

Table of Contents
loading

Table of Contents