Overall Menu Flowchart; Figure 29 - Programming Menu Flowchart - Ametek OXYvisor Installation, Operation & Maintenance Manual

Optical oxygen analyzer for use with bosx optical sensors
Table of Contents

Advertisement

Section 5
Operations

5.10 Overall Menu Flowchart

Measurement
& Units
Oxygen
BOS1
Sensor Type
BOS2
BOS3
Gas Phase Oxygen
Media
Measurement
Aqueous Liquids
(Contains Water)
Non-Aqueous Liquids
(No Water)
Oxygen Units
ppm Oxygen (gas)
%Oxygen (gas)
hPa (gas)
% Air Saturation (gas)
ppm Oxygen (Liquid)
ppb Oxygen (Liquid)
hPa (gas)
Compensation Units
Oxygen
Auto Adjust
Normal Sample Rate
Sample Rate
Max Sample Rate
Manual
Adjust
Change for Max Sample Rate
Signal
10 - 100%
Intensity
*Pulse Length
*Automatic
* Only accessible in advanced
*Manual Adjust

Figure 29 - Programming Menu Flowchart

48
Installation, Operation and Maintenance Manual
User Defined
f1
Constants
dPhi1
dPhi2
dKsv1
dKsv2
m
Humidity Present (> 50%)
Std Pressure Compensation
Correction For Dissolved Salts
(Ideal Gas Law)
Salinity Concentration Input
**AGI Compressibility
(Natural Gas Only)
Non-Compressible Liquids
**Compressible Liquids
**Equations of State
** Only Accessible in Software
Temperature Units
Process Pressure Units
mBar
(Absolute)
inches H2O
Bar
Torr
PSI
OXYvisor Optical Oxygen Analyzer
Calibration
Last Cal
Basic Setup
Status
Advanced
Factory O2
Setup
Sensor
Calibration
Enter Span Calibration Point
Enter Span Cal Phase Angle
Enter Calibration Temperature
Enter Atmospheric Pressure
Manual O2
Cal-Temp On
Calibration
Cal-Temp Off
Enter Temp
*Auto O2
Calibration
Description
Setup
Is Humidity Present During Cal
Use Ambient Pressure Sensor
Fahrenheit
*Initiate O2
Auto
Celsius
Calibration
*Temperature
Sensor
Calibration
Pressure Sensor Analog Input
*Pressure
Sensor
Calibration
Ambient Temperature Sens
Datalogging
Error Log
Last 10 errors
Calibration
Log
Data Log
Status
Download
Log File
Data Trend
Parameter to
Setup
log
Process Temperature
Enter Zero Phase Angle
Send Factory Cal Data
Zero Gas Calibration
Single Point Calibration
Span Gas Calibration
Two Point Calibration
Zero Gas Calibration
Is Humidity Present During Cal
Span Gas Calibration
Use Ambient Pressure Sensor
Manual Pressure Input
Schedule (1
, 2
, 3
, 4
)
st
nd
rd
th
Yes / No
Calibration
Calibration
Calibration Time and Interval
Frequency
Interval Between Calibrations
Time to Next
Calibration
Manual Pressure Input
Enter Span Gas Value
Zero Cal Drift Tolerance
Span Cal Drift Tolerance
Zero Gas Purge Time
* Only accessible in advanced
Span Gas Purge Time
Calibration Recovery Time
Enable Auto Calibration
Start Auto Calibration – 1
st
Time
Start Auto Calibration
Press Esc to Stop AutoCal
PT100 / PT1000 RTD
Calibration
Calibration
OR
Calibration
Start data logging
Stop data logging
.csv File
.txt Delimited File
Oxygen
Process Pressure
Phase Angle
Signal Intensity
Input Span
Gas
Input Span
Gas
Time Calibration Should Occur
Time Calibration Should Occur