Ametek OXYvisor Installation, Operation & Maintenance Manual page 49

Optical oxygen analyzer for use with bosx optical sensors
Table of Contents

Advertisement

Installation, Operation & Maintenance Manual
OXYvisor Optical Oxygen Analyzer
Input Output
Output Hold
Action
Temperature
PT100 Sensor (4 Wire)
Input
PT1000 Sensor (2 Wire)
Temperature –
Enter 4mA Temperature Value
External Analog Input
Temperature – Manual Input
Pressure
Ambient Pressure Sensor
Sensor Input
Pressure – External Analog
Input
Enter 20mA Pressure Value
Pressure – Manual Input
Analog
Enable Analog Output
Output (1&2)
Oxygen
Process Temperature
Phase Angle
Intensity
Process Pressure
Output Signal Critical Fault
Digital Output
Oxygen
(1 to 4)
Error Code
Process Pressure
Process Temperature
Auto Cal – (Relays 1,2,3)
Remote
Digital Input 1 - Auto Cal
Digital Input
Digital Input 2 - Test Gas Insert
Enter 20mA Temperature
Value
Enter 4mA Pressure Value
Linear
Enter 4mA O2 Value
Bi-Linear
Enter 4mA O2 Value
Enter 20mA O2 Value
Enter 20mA O2 Value
Bi-Linear Point (mA)
Bi-Linear Point Oxygen
Reading
Fault Direction
High (20mA)
Enable NAMUR Signaling
Low (4mA)
Set-Point
General Error
Normal State
Code
Specific Error
Code
Normal State
Open
Deadband
Closed
Time period for Test Gas
Define which output
DO1 - Zero Gas
DO2 - Span Gas
Open
Closed
Actuate on Low Oxygen /
Temperature / Pressure
Actuate on Low Oxygen /
Temperature / Pressure
Diag-Test
Security
System
S/N, Model#, FW Version
Overview
MFG Date, E-mail
Test Gas
Start Test Gas Insert
Initiate Test Gas Insert
Insert
Stop Test Gas Insert
Set Date /
Set Date
Set Time
AM / PM
Time
Display
Contrast
Backlight
Backlight time-out
10s, 30s, 60s, 5min, never
Backlight brightness
Security
HMI Lock-Out
All Submenus
Enter Code
Measurement & Unit Submenu
Enter Code
Calibration Submenu
Enter Code
Input / Output Submenu
Enter Code
Enter Code
Diag Test Security Submenu
Datalogging Submenu
Enter Code
Analog
4mA Out
Output Trim
(1&2)
20mA Out
Relay
Close
(1 to 4) Test
Open
Relay
(1 to 4) Test
Firmware
Upgrade
Reset to
Factory
Defaults
Help Error Codes
X11
Signal intensity too low. Check process gas.
X22
Signal intensity too high. Turn LED down.
N25
Ambient Pressure reading is out of range
N42
Zero phase angle is out of allowed limits. Check..
N43
Span phase angle is out of allowed limits. See ....
N54
Analog Output 2 is open. Check wiring. Note...
Section 5
Operations
Enable
Disable
49