2�7�3 Class I, Division 2 Groups A,B,C, & D; Product Label / Name Plate - (Pending Final Approvals); Product Label / Name Plate Overview (Pending Final Approvals); Figure 6 - Oxyvisor Product Label / Name Plate - Ametek OXYvisor Installation, Operation & Maintenance Manual

Optical oxygen analyzer for use with bosx optical sensors
Table of Contents

Advertisement

Installation, Operation & Maintenance Manual
OXYvisor Optical Oxygen Analyzer
IECEx Zone 2, Group IIC Markings:
Certificate Number:
Standards:
North American Zone 2, Group IIC Markings:
US Standards:
CAN Standards:
2�7�3 Class I, Division 2 Groups A,B,C, & D
The OXYvisor is certified as Process Control Equipment for use in hazardous locations (QUZW, QUZW7)
Class I, Division 2 Groups A, B, C, & D
US Standards:
CAN Standards:

2.8 Product Label / Name Plate - (Pending Final Approvals)

2.8.1 - Product Label / Name Plate Overview (Pending Final Approvals)

The Product Label (Name Plate) is found at the top of the analyzer (Figure 4). The product label identifies
important information and attributes of the specific model and should be reviewed in detail prior to installation.
Branding Logo
Serial # contains the
date of manufac-
ture. The rst four
numbers are YYMM
Power: Acceptable
range, power type
and max wattage
drawn
Parent Company
Logo

Figure 6 - OXYvisor Product Label / Name Plate

Ex ec ic op is IIC T4 Gc
IECEx UL 18.003Xx
IEC 60079-0,
IEC 60079-7,
IEC 60079-11,
IEC 60079-28,
IEC 61010-2-201
Class 1 Zone 2 AEx ec ic op is IIC T4 Gc
Class 1 Zone 2 Ex ec ic op is IIC T4 Gc
UL 60079-0,
UL 60079-7,
UL 60079-11,
UL 60079-28,
CSA C22.2 No. 60079-0,
UL 60079-7
UL 60079-11,
UL 60079-28,
Class I, Division 2, Groups A, B, C, & D T4A
UL 12.12.01 - Edition 9 Issued 2017/09/15
CSA C22.2 No. 213-17 - Edition 3 Issued 2017/09/15
Made in Carson City NV - USA
www.BarbenAnalytical.com
BOA-DC-1-SFP-B-SI
Model#
Serial #
YYMM -0000-1234XYZ
21.6 - 26.4 VDC
Power:
5 Watts
WARNING: Consult Conditions of Safe Use in installation
!
manual and DWG# 2P0345 to preserve the protection
a orded by the equipment.
AVERTISSEMENT: Consultez les conditions d'utilisation
!
sécurisée du manuel d'installation et le DWG n° 2P0345
pour préserver la protection o erte par l'équipement.
RoHS
Edition 6,
Issued 2014-10
Edition 5.1,
Issued 2014-06
Edition 6,
Issued 2014-10
Edition 2,
Issued 2015-05
Edition 1,
Issued 2013
Edition 6,
Dated 2017/10/20
Edition 5.1,
Dated 2017/04/21
Edition 6,
Dated 2014/03/28
Edition 2,
Dated 2017/12/08
Edition 3,
Issue Date 2015/10/01
Edition 2,
Issue Date 2016/
Edition 2,
Issue Date 2014/02/01
Edition 1,
Issue Date 2016/
OXYvisor
II 2 G
Ex db op is IIC T4 Gb
Ex db op is IIC T4 Gb
0539
Class I Zone 1
AEx db op is IIC T4 Gb
Ex db op is IIC T4 Gb
Ta = -20°C to +55°C, IP 66, NEMA 4x
E502700 Process Control Equipment for
Use in Zone Classi ed Hazardous Locations
Installation DWG# 2P0345
DEMKO 18 ATEX 2031
IECEx UL 18.0033
!
WARNING: Do not open when an explosive
atmosphere is present. Seal all cable exits in
accordance with government and local code.
!
AVERTISSEMENT:
Ne pas ouvrir quand une atmosphère
explosive est présente. Sceller toutes les sorties de câbles
conformément aux codes gouvernementaux et locaux.
Technical Product Specification
Product Name
Hazardous Area Markings
Installation Drawing
contains critical informa-
tion about the installation
requirements. This must
be reviewed prio to instal-
laltion.
Important Warnings! that
should be adhered to at
all times.
Section 2
19

Hide quick links:

Advertisement

Table of Contents
loading