[1]
[1]
[2]
F-3-151
3.5.6.2 Removing the Feed
Guide
1) Open the open/close guide [1]; then, remove the 2
screws [2], and disconnect the connector [3] to detach
the feed guide [4].
[2]
[4]
[3]
F-3-152
0004-5588
[1]
3.5.6.3 Removing the Read
Sensor
1) Remove the 2 screws [1], and disconnect the
connector [2]; then, detach the read sensor [3].
[1]
[2]
F-3-153
If you have replaced the sensor PCB, be sure to
perform sensor adjustment.
3.5.7 Delivery Reversal Sensor
3.5.7.1 Removing the Open/
Close Guide
1) Remove the segment A, and detach the open/close
guide [1] in the direction of the arrow.
F-3-154
Chapter 3
0004-0541
[3]
0004-0731
[1]
[A]
3-39