FujiFilm FVR-Micro Instruction Manual page 38

Advanced simple inverter
Table of Contents

Advertisement

Code
Name
F02
Operation Method
F03
Maximum Frequency 1
F04
Base Frequency 1
F05
Rated Voltage at Base
Frequency 1
F06
Maximum Output
Voltage 1
F07
Acceleration Time 1
F08
Deceleration Time 1
F09
Torque Boost 1
F10
Electronic Thermal Overload
Protection for Motor 1
(Motor characteristics)
(Overload detection level)
F11
(Thermal time constant)
F12
F14
Restart Mode after Momentar
Power Failure
(Mode selection)
F15 Frequency Limiter (High) (Low 0.0 to 400.0
F16
Data setting range
0: RUN/STOP keys on keypad (Motor
rotational direction specified by terminal
command FWD/REV)
1: Terminal command FWD or REV
2: RUN/STOP keys on keypad (forward)
3: RUN/STOP keys on keypad (reverse)
25.0 to 400.0
25.0 to 400.0
0: Output a voltage in proportion to input
voltage
80 to 240: Output an AVR-controlled
voltage (for 200 V class series)
160 to 500: Output an AVR-controlled
voltage (for 400 V class series)
80 to 240: Output an AVR-controlled
voltage (for 200 V class series)
160 to 500: Output an AVR-controlled
voltage (for 400 V class series)
0.01 to 3600
Note: Entering 0.00 cancels the acceleration
time, requiring external soft-start.
0.01 to 3600
Note: Entering 0.00 cancels the deceleration
time, requiring external soft-start.
0.0 to 20.0
(percentage with respect to "F05: Rated
Voltage at Base Frequency 1")
Note: This setting takes effect when F37 = 0,
1, 3, or 4.
1: For a general-purpose motor with shaft-
driven cooling fan
2: For an inverter-driven motor with
separately powered cooling fan
0.00: Disable, 0.01 to 100.0
1 to 135% of the rated current (allowable
continuous drive current) of the motor
0.5 to 75.0
0: Disable restart (Trip immediately)
1: Disable restart (Trip after a recovery from
power failure)
2: Trip after decelerate-to-stop *2
4: Enable restart (Restart at the frequency
at which the power failure occurred, for
general loads)
5: Enable restart (Restart at the starting
frequency)
0.0 to 400.0
Incre-
ment
0.1
0.1
1
1
0.01
0.01
0.1
0.01
0.1
0.1
0.1
5-3
Change
Data
Default
Unit
when
copying
running
setting
N
Y
2
Hz
N
Y
60.0
60.0
Hz
N
Y
0
V
N
Y2
220
V
N
Y2
(380)
s
Y
Y
6.00
s
Y
Y
6.00
%
Y
Y
See Table A.
Y
Y
1
A
Y
Y1
See Table A.
Y2
min
Y
Y
5.0
1
Y
Y
Hz
Y
Y
70.0
Hz
Y
Y
0.0