7.5.17 Pdf417 Code Selection; Figure 7.40: Configuration Codes For Activating/Deactivating The Pdf417 Code Type - Leuze electronic LSIS 222 Technical Description

Code reader
Table of Contents

Advertisement

7.5.17 PDF417 code selection

By reading in one of the following configuration codes, reading of the PDF417 code type is
activated or deactivated. In addition, it is possible to configure the number of digits that are
to be read (value range for number of digits: 1 ... 2750, factory setting: 1 ... 2750).
PDF417 - standard settings
PDF417 - minimum number of digits

Figure 7.40: Configuration codes for activating/deactivating the PDF417 code type

Notice!
To set the minimum or maximum number of digits, please first read in the above configura-
tion code and then the digits for the desired number of digits (see "Programming codes for
the configuration" on page 92). Conclude parameter entry by reading in the Save program-
ming code.
Leuze electronic
Read code type PDF417 ON
Technical description LSIS 22x
Configuration using configuration codes
Read code type PDF417 OFF
PDF417 - maximum number of digits