7.2.1

Manual/serial trigger mode

By reading in one of the following configuration codes, the manual/serial trigger mode is
set to either the normal or enhanced variant.
Manual/serial trigger mode - normal
Figure 7.6:
Read time-out for serial trigger
If the reading gate is to be closed after sending the <SYN>T<CR> read start command if
no code was read after a defined time, you can set a read time-out time. Values can be
set in the range 0 ... 300,000ms.
To do this, first read in the following configuration code and then, digit by digit, the
programming codes (see "Programming codes for the configuration" on page 92) for the
numerical value of the read time-out time in milliseconds. Conclude parameter entry by
reading in the Save programming code.
Figure 7.7:
Shown below is an example illustrating the principle for entering a parameter value.
Leuze electronic
Configuration codes for setting the manual/serial trigger mode
Configuration code for setting the read time-out time
Technical description LSIS 22x
Configuration using configuration codes
Manual/serial trigger mode - enhanced
Read time-out
35