Reading Multiple Different Codes In One Reading Gate; Figure 7.13: Configuration Code For Setting The Read Time-Out Time; Figure 7.14: Configuration Codes For Switching The Multiple Read Option On/Off - Leuze electronic LSIS 222 Technical Description

Code reader
Table of Contents

Advertisement

Configuration using configuration codes
To do this, first read in the following code and then, digit by digit, the programming codes
(see "Programming codes for the configuration" on page 92) for the numerical value of the
reread delay time in milliseconds. Conclude parameter entry by reading in the Save
programming code.

Figure 7.13: Configuration code for setting the read time-out time

To illustrate the principle of parameter value entry, see example on page 36.
7.3.2

Reading multiple different codes in one reading gate

By activating the multiple read option, multiple codes can simultaneously be read in one
reading gate. The LSIS 22x attempts to find new codes in the read field as long as the
reading gate is open. If the option is deactivated (factory setting), the LSIS 22x reads the
code that is closest to the target beam and, thus, to the center of the read field.
By reading in one of the following configuration codes, the multiple read option is set on
or off.

Figure 7.14: Configuration codes for switching the multiple read option on/off

40
Application-specific reread delay time
Multiple read ON
Technical description LSIS 22x
Multiple read OFF
Leuze electronic