Configuration using configuration codes
7.2.3
Streaming presentation mode
By reading in one of the following configuration codes, streaming presentation mode is
set to either the normal or enhanced variant.
Streaming presentation mode - normal
Figure 7.11: Configuration codes for setting the streaming presentation mode
Attention!
If a trigger occurs by means of a button or trigger input while the LSIS 22x is in
presentation mode, the LSIS 22x switches to manual/serial trigger mode!
Each time the trigger button is pressed or trigger input is activated, the LSIS 22x is again
activated as long as the trigger button is pressed or a high-signal is applied at the trigger
input.
If no trigger is initiated via the button or the switching input for the duration of the hands
free time-out time (factory setting: 5s), the LSIS 22x returns to presentation mode.
In manual/serial trigger mode, the hands free time-out time is not active.
See "Configuring the hands free time-out time" on page 37.
38
Technical description LSIS 22x
Streaming presentation mode - enhanced
Leuze electronic