  • Page 3: Table Of Contents

    Mounting with M4 fastening screws .................. 30 6.2.2 Mounting with the BTU 320M-D12 mounting system ............ 30 6.2.3 Mounting with the BT 320M mounting bracket .............. 31 6.2.4 Mounting with the BTU 320M-D12-RL70 mounting bracket.......... 31 Replace housing hood ...................... 31 Attaching the diffusor foil ......................  32 Leuze electronic DCR 202i...
  • Page 4 10.1.2 General online commands .................... 56 10.1.3 Online commands for system control ................ 61 10.2 XML-based communication .................... 61 Care, maintenance and disposal ............... 62 Diagnostics and troubleshooting.............. 63 Service and support ................... 64 13.1 What to do should servicing be required? ................ 64 Leuze electronic DCR 202i...
  • Page 5 15.3 Optical accessories.......................  73 15.4 Cables accessories.......................  73 15.5 Other accessories .........................  74 EC Declaration of Conformity................ 76 Appendix...................... 77 17.1 ASCII character set.......................  77 17.2 Code samples ........................ 80 17.3 Configuration via configuration codes...................  82 17.4 License terms........................ 83 Leuze electronic DCR 202i...
  • Page 6: About This Document

    Regular expressions for reference code comparison (Perl Compatible Regular Expressions) PELV Protective extra low voltage with reliable disconnec- tion (Protective Extra Low Voltage) Region of interest of the code reader (Region of In- terest) Programmable Logic Control Leuze electronic DCR 202i...
  • Page 7 About this document TCP/IP Internet protocol family (Transmission Control Pro- tocol/Internet Protocol) Network transmission protocol (User Datagram Pro- tocol) Underwriters Laboratories Leuze electronic DCR 202i...
  • Page 8: Safety

    Ä The device may only be opened for exchanging the housing hood. Stainless stainless steel housings must not be opened. Ä There are no user-serviceable parts inside the device. Ä Repairs must only be performed by Leuze electronic GmbH + Co. KG. Leuze electronic DCR 202i...
  • Page 9: Competent Persons

    Leuze electronic GmbH + Co. KG is not liable in the following cases: • The device is not being used properly. • Reasonably foreseeable misuse is not taken into account. • Mounting and electrical connection are not properly performed. • Changes (e.g., constructional) are made to the device. Leuze electronic DCR 202i...
  • Page 10: Device Description

    • Two control buttons for intuitive operation without PC • Industrial design: degree of protection IP 65 acc. to EN 60529 (Device with stainless steel housing: degree of protection IP 67/69K) • Diverse mounting options with mounting threads on rear and side surfaces Leuze electronic DCR 202i...
  • Page 11: Accessories

    • MA 2xxi modular connection units for connection to fieldbus systems (see chapter 7.6 "Connecting code reader to fieldbus") • MA 150 modular connection unit for decentralized distribution of the signals (see chapter 7.7 "Connect- ing code reader to MA 150 connection unit") Leuze electronic DCR 202i...
  • Page 12: Device Construction

    Control panel with indicator LEDs, control buttons, bar graph display Device with stainless steel housing: indicator LEDs LEDs for illumination (red light) M4 mounting thread Device housing Housing hood M12 connection technology Feedback LED (green) Fig. 3.1: Device construction Leuze electronic DCR 202i...
  • Page 13: Connection Technology

    • Three indicator LEDs (PWR, NET, LINK) • Six-level bar graph display for function selection and display of the reading quality (SIGNAL QUALITY) – not with devices with stainless steel housing • Two control buttons – not on devices with stainless steel housing Leuze electronic DCR 202i...
  • Page 14: Led Indicators

    • Self test successfully finished • Device monitoring active Orange ON (continuous light) Service mode • Code reading possible • No data on the host interface Flashing Wave function (synchronous with NET LED) • Code reading possible Leuze electronic DCR 202i...
  • Page 15 NET indicator only for Ethernet communication! The NET indicator refers only to the Ethernet communication, not to the RS 232/RS 422. LINK LED Tab. 3.3: LINK indicators Color State Description Green ON (continuous light) Ethernet connected (LINK) Yellow Flashing Data communication (ACT) Leuze electronic DCR 202i...
  • Page 16 •    – Navigation button: Scroll through the functions in the bar graph display from left to right. •    – Navigation button: Scroll through the functions in the bar graph display. Leuze electronic DCR 202i...
  • Page 17 Ä Press the navigation button  . ð The TRIG LED flashes and the Trigger function is preselected. Ä Press the enter button  ð The TRIG LED illuminates continuously. ð The configured Trigger function (e.g., reading gate control) is started. Leuze electronic DCR 202i...
  • Page 18: Functions

    • As soon as the decoding result corresponds to the settings, the decoding stops the capture of the re- maining images. Continuous image capture Decoding Output of the read data Fig. 4.1: "Burst mode" camera operating mode Leuze electronic DCR 202i...
  • Page 19: Presentation Mode

    Regular expressions can only be entered via the webConfig tool (see chapter 9 "Commissioning – Leuze electronic webConfig tool"). Detailed information on regular expressions can be found on the Internet under Perl Compatible Regular Expressions (PCRE) http://www.pcre.org/. Leuze electronic DCR 202i...
  • Page 20: Code Quality

    • Output of each feature via the interface and as a programmable switching output ISO/IEC 15416 mode: Individual features for bar codes • Overall quality • Symbol contrast (SC) • Modulation (MOD) • Decodability • Minimal edge contrast (EC • Minimal reflectance (R • Defects • Decodes Leuze electronic DCR 202i...
  • Page 21: Leuze Webconfig Tool

    The webConfig configuration tool offers a graphical user interface for the configuration of the code reader via a PC (see chapter 9 "Commissioning – Leuze electronic webConfig tool"). The wizard of the webConfig tool can be used to easily configure the code reader in just a few steps. Leuze electronic DCR 202i...
  • Page 22: Applications

    Applications Applications Reading of 1D-codes Fig. 5.1: Reading of 1D-codes Leuze electronic DCR 202i...
  • Page 23: Reading Of 2D-Codes

    Using the polarization filter By using the linear polarization filter integrated in the housing hood, you can avoid interfering reflections. NOTICE When the polarization filter is used, the exposure settings change. The exposure time is in- creased considerably. Leuze electronic DCR 202i...
  • Page 24: Code Reading With Diffusor Foil

    Code reading with diffusor foil Fig. 5.4: Using the diffusor foil The diffusor foil reduces interfering reflections by increasing the scatter of the integrated LED illumination of the code reader. NOTICE When the diffusor foil is used, the exposure settings change. Leuze electronic DCR 202i...
  • Page 25: Mounting

    • The permissible line lengths between code reader and host system depending on which interface is used. • Visibility of the control panel and access to the control buttons. • No direct sunlight and/or no strong ambient light on the code that is to be read. Leuze electronic DCR 202i...
  • Page 26: Avoiding Total Reflection

    For the relationship between camera distance and reading field size, see the section "Relationship between camera distance and reading field size". Leuze electronic DCR 202i...
  • Page 27 0.127 mm (5 mil) 0.19 mm (7.5 mil) 2D-Codes 0.25 mm (10 mil) 0.5 mm (20 mil) [mm] Reading distance [mm] Fig. 6.2: Typical reading distances for 1D- and 2D-codes with various modulus sizes of the codes Leuze electronic DCR 202i...
  • Page 28 0.19 mm (7.5 mil) 0.25 mm (10 mil) 2D-Codes 0.35 mm (14 mil) 0.5 mm (20 mil) [mm] Reading distance [mm] Fig. 6.3: Typical reading distances for 1D- and 2D-codes with various modulus sizes of the codes Leuze electronic DCR 202i...
  • Page 29 The camera distance is the path from the front edge of the code reader to the code. Camera distance Reading field Height of the reading field Width of the reading field Fig. 6.5: Camera distance and read field Leuze electronic DCR 202i...
  • Page 30: Mounting The Code Reader

    Ä Mount the mounting system on the rod with the clamp profile (system-side). Ä Mount the device to the mounting system with M4 fastening screws. ð Max. tightening torque of the fastening screws: 1.4 Nm ð Location and thread depth of the mounting thread: see chapter 14.3 "Dimensioned drawings" Leuze electronic DCR 202i...
  • Page 31: Mounting With The Bt 320M Mounting Bracket

    Ä First tip the housing hood downward and away from the housing base. Ä Then lift the housing hood up and off of the housing base. Ä Then mount the new housing hood in the reverse order. The tightening torque of the fastening screws is 0.25 Nm. Leuze electronic DCR 202i...
  • Page 32: Attaching The Diffusor Foil

    Ä Make certain that the diffusor foil is correctly oriented. Small recess at top, large recess at bottom. Fig. 6.8: Orientation of the diffusor foil Ä Attach the diffusor foil to the housing screen from bottom to top. Fig. 6.9: Attaching the diffusor foil Leuze electronic DCR 202i...
  • Page 33 Mounting NOTICE Avoid air bubbles when attaching the diffusor foil! Ä When attaching the diffusor foil, take care to prevent bubbles from forming under the film. Leuze electronic DCR 202i...
  • Page 34: Electrical Connection

    Overview The code reader is provided with the following connections: • PWR / SWIO: A-coded, 12-pin, M12 connection for operating voltage, switching inputs/outputs, RS 232/RS 422 interface • HOST: D-coded, 4-pin, M12 connection for the Ethernet connection Leuze electronic DCR 202i...
  • Page 35: Pwr / Swio - Voltage Supply / Rs 232/Rs 422 / Switching Inputs/Outputs

    PWR / SWIO – voltage supply / RS 232/RS 422 / switching inputs/outputs 12-pin M12 plug (A-coded) Fig. 7.2: PWR / SWIO connection Tab. 7.1: PWR / SWIO pin assignment Designation Core color Assignment Brown +18 … +30 V DC operating voltage GNDIN Blue Negative operating voltage (0 V DC) Leuze electronic DCR 202i...
  • Page 36 The shield of the connection cable is on the thread of the M12 plug. NOTICE The core colors only apply if Leuze electronic’s original connection cables are used (see chapter 15.4 "Cables accessories"). NOTICE UL applications! For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na- tional Electric Code).
  • Page 37 ð If, for example, the inverted sensor output is connected to pin 2, and pin 2 of the code reader is, at the same time, configured as a switching output (and not as a switching in- put), the switching output malfunctions. Leuze electronic DCR 202i...
  • Page 38: Host - Host Input / Ethernet

    • The device supports the following protocols and services: • TCP / IP (client/server) • UDP • DHCP • ARP • PING • For communication with the superior host system, the corresponding TCP/IP protocol (client/server mode) or UDP must be selected. Leuze electronic DCR 202i...
  • Page 39 Self-configured cables with Ethernet interface! Ä Ensure adequate shielding. Ä The entire interconnection cable must be shielded and earthed. Ä The RD+/RD- and TD+/TD- wires must be stranded in pairs. Ä Use at least a CAT 5 cable for the connection. Leuze electronic DCR 202i...
  • Page 40: Cable Lengths And Shielding

    The following components can be connected to the MA 150 connection unit: • Code reader of the DCR 200i series • Photoelectric sensor/diffuse sensor to activate the code reader • Voltage supply • External illumination • Serial communication RS 232/RS 422 Leuze electronic DCR 202i...
  • Page 41 Cable, M12 connector/open cable end, 5-pin, 2 m e.g., 50108595 Cable, M12 socket/open cable end, 5-pin, 2 m e.g., 50104555 Cable, M12 socket/connector, 4-pin, 2 m e.g., 50110126 Cable, M12 socket/connector, 12-pin, 2 m e.g., 5030284 Fig. 7.8: Circuit diagram example with MA 150 connection unit Leuze electronic DCR 202i...
  • Page 42: Starting Up The Device - Basic Configuration

    • GS1 DataBar EXPANDED; number of digits: 14 … 21 • GS1 DataBar TRUNCATED; number of digits: 14 • DataMatrix code ECC200; number of digits: 10x10 … 144x144, or 8x18 … 16x48 • QR code; number of digits: 11x11 … 161x161 • Aztec code; number of digits: 11x11 … 151x151 Leuze electronic DCR 202i...
  • Page 43: Setting The Communication Parameters

    Configuration > Control > Ethernet DCR NOTICE The device cannot be accessed if the IP address is incorrect! Ä Make certain that the correct IP address is entered. The device can otherwise no longer be accessed. Leuze electronic DCR 202i...
  • Page 44: Automatically Setting The Ip Address

    8.3.3 Address Link Label The "Address Link Label" is an additional stick-on label that is affixed to the device. 00:15:7B:20:00:15 DCR 202i MAC Name Fig. 8.1: Example of an "Address Link Label"; the device type varies depending on the series • The "Address Link Label" contains the MAC address (Media Access Control address) of the device and makes it possible to enter the IP address and the device name manually.
  • Page 45: Ethernet Host Communication

    If there is a connection request and a connection is established by the superior host system (PC/ control as client), the device – in server mode – accepts the connection. Data can then be sent and received. Leuze electronic DCR 202i...
  • Page 46: Rs 232/Rs 422 Communication

    Ä You can set the time stamp via Maintenance > System clock. ð The system clock is reset if the operating voltage is interrupted. Configuration via configuration codes You can make configuration changes with the help of configuration codes (see chapter 17.3 "Configuration via configuration codes"). Leuze electronic DCR 202i...
  • Page 47: Activating Device Functions

    With activation of the teach function, a present code is taught-in as a reference code. During the teach event, the reading gate is opened and a code located in the read field is decoded. The de- coded code is stored as a new reference code in the device. Leuze electronic DCR 202i...
  • Page 48: Performing Further Settings

    • Read in a reference code • Start automatic code type configuration (AUTO function) • Start alignment mode Ä Connect the required control devices, e.g., photoelectric sensor, proximity switch, etc., to the device (see chapter 7 "Electrical connection"). Leuze electronic DCR 202i...
  • Page 49: Activating Camera Operating Mode

    Ä Connect the required switching outputs (see chapter 7 "Electrical connection"). Ä Configure the connected switching outputs according to your requirements. ð First set the I/O mode to output ð Then configure the switching behavior. ð webConfig tool: Configuration > Control > Digital I/Os Leuze electronic DCR 202i...
  • Page 50: Optimizing Reading Performance

    With the webConfig tool, you can store complete device configurations on data carriers and transfer them from these to the device: Maintenance > Backup/Restore This storage of configuration data is especially useful if you want to store basic configurations which will re- quire only minor changes. Leuze electronic DCR 202i...
  • Page 51: Commissioning - Leuze Electronic Webconfig Tool

    • Current decoding result • Brief history of the last decoding operations • States of the switching inputs/outputs • Statistics counter NOTICE The process information may be displayed with a time delay depending on the current process- ing speed. Leuze electronic DCR 202i...
  • Page 52: Short Description Of The Webconfig Tool

    Short description of the webConfig tool The menus and dialog boxes of the webConfig tool are intuitive to operate and provide texts and tool tips. The start page of the webConfig tool displays the current process information. Leuze electronic DCR 202i...
  • Page 53: Change Operating Mode

    Menu options of the webConfig tool The webConfig tool offers the following menu functions: • PROCESS • Information on the current read result • Current camera image • Status of the switching inputs/outputs • Reading statistics Leuze electronic DCR 202i...
  • Page 54: Configuration Menu

    • [Start wizard]: Quick configuration in just a few steps • [Edit project]: Configuration via the full view of the webConfig tool • [Load project from PC]: Configuration via an existing configuration project • [Save project on PC]: Save configuration project Leuze electronic DCR 202i...
  • Page 55: Configuring Applications With The Wizard

    With the configuration wizard, you can set up your application in just a few steps. Fig. 9.4: Configuration wizard Ä Select CONFIGURATION > [Start Wizard]. Ä Make the settings using the configuration steps presented by the wizard. NOTICE The settings are not saved until the final configuration step (FINISH) is performed. Leuze electronic DCR 202i...
  • Page 56: Interfaces - Communication

    Example: ’DCR 202i FIX-F1-102-R2 V1.0.0 2016-01-01’ The first line contains the device type of the code reader, followed by the device ver- sion number and version date. The data which is actually displayed may vary from the values given here. Leuze electronic DCR 202i...
  • Page 57 • Permanently store found code types and number of digits in the decoder table. This is performed if a configuration code is present! Parameter ’+’ Activates Auto setup Acknowledgment ’CS=x’ Status ’00’ Valid ’CA’ command ’01’ Invalid command ’02’ ‘Auto setup' could not be activated Leuze electronic DCR 202i...
  • Page 58 These values can be used to determine the reading quality or decoding quality. The values are also output on the bar graph display of the device (SIGNAL QUAL- ITY). Parameter ’+’ activates the alignment mode ’-’ deactivates the alignment mode Acknowledgment ’yyy zzzzzz’ Reading quality in [%]. zzzzzz Code information Leuze electronic DCR 202i...
  • Page 59 Defined code type (see command 'CA') Defined code information (1 … 244 characters) NOTICE With this function, only code types are recognized that are identified using the Auto setup func- tion or which were set in the setup. Leuze electronic DCR 202i...
  • Page 60 Service operating mode Device error ’1’ Device error, no inspection possible ’0’ No device error, ready 3 … 7 No function, value is always ’0’ Alternatively, the following acknowledgment is output: ’DS=xx’ Error acknowledgment ’00’ Syntax error ’01’ Other error Leuze electronic DCR 202i...
  • Page 61: 10.1.3 Online Commands For System Control

    You can find detailed information on XML-based communication on the Leuze home page: www.leuze.com • Enter the type designation or part number of the device as the search term. • You can find the information on the Downloads tab. Leuze electronic DCR 202i...
  • Page 62: Care, Maintenance And Disposal

    Repairs to the device must only be carried out by the manufacturer. Ä For repairs, contact your responsible Leuze electronic subsidiary or Leuze electronic customer service (see chapter 13 "Service and support"). Disposing Ä For disposal observe the applicable national regulations regarding electronic components. Leuze electronic DCR 202i...
  • Page 63: Diagnostics And Troubleshooting

    • Contact Leuze electronic customer service • Hardware error (see chapter 13 "Service and support") Red, continuous Network error Check interface light No communication established to the IO controller Red, flashing No communication Check interface Parameterization or configuration failed Leuze electronic DCR 202i...
  • Page 64: Service And Support

    Ä Enter the contact information and fax this form together with your service order to the fax number given below. Customer data (please complete) Device type: Serial number: Firmware: Status of LEDs: Error description: Company: Contact person/department: Phone (direct dial): Fax: Street/No: ZIP code/City: Country: Leuze Service fax number: +49 7021 573 - 199 Leuze electronic DCR 202i...
  • Page 65: Technical Data

    Fastening 2 M4 threaded inserts on each of the side walls, 5 mm deep 4 M4 threaded inserts on the rear, 3.5 mm / 5 mm deep Housing Housing: polycarbonate Housing base: diecast aluminum Optics cover Polycarbonate Optional: glass Leuze electronic DCR 202i...
  • Page 66: Optical Data

    CSA C22.2 No. 60950-1-07 Conformity CE, FCC, UL Chemical resistance Stainless steel housing tested in accordance with ECOLAB and Clean- Proof+ (see Leuze electronic website at www.leuze.com) 14.2 Optical data Integrated LED illumination Red light (visible, 616 nm) Risk group 0 (exempt group) Acc.
  • Page 67: 14.2.1 Reading Performance

    GS1 DataBar (Omnidirectional, Expanded, Limted, Truncated) codes GS1 DataBar (Stacked Omnidirectional, StackedExpanded) PDF417 Code type: 2D DataMatrix (ECC200), Aztec Code, GS1 Aztec Code, GS1 DataBar (ECC200) QR-Code, GS1 QR-Code 14.3 Dimensioned drawings all dimensions in mm A Optical axis Fig. 14.1: DCR 200i dimensioned drawing Leuze electronic DCR 202i...
  • Page 68: Dimensioned Drawings - Accessories

    Technical data all dimensions in mm A Optical axis Fig. 14.2: Dimensioned drawing of DCR 200i with stainless steel housing 14.4 Dimensioned drawings - Accessories all dimensions in mm Fig. 14.3: Dimensioned drawing of the BTU 320M-D12 mounting system Leuze electronic DCR 202i...
  • Page 69 Technical data all dimensions in mm Fig. 14.4: Dimensioned drawing of the BT 320M mounting bracket Leuze electronic DCR 202i...
  • Page 70 Technical data all dimensions in mm Fig. 14.5: Dimensioned drawing of the BTU 320M-D12-RL70 mounting bracket for ring light Leuze electronic DCR 202i...
  • Page 71 IDENT SWO2 SWI1 HOST Art.-No. MA 150 0130109 all dimensions in mm Earthing strap Green LED: PWR White LED: SWI1 White LED: SWO2 White LED: SWIO3 White LED: SWIO4 Fig. 14.6: Dimensioned drawing of MA 150 connection unit Leuze electronic DCR 202i...
  • Page 72: Order Guide And Accessories

    A list with all available device types can be found on the Leuze electronic website at www.leuze.com. 15.2 Type overview Tab. 15.2: Type overview Type designation Description Part no. DCR 202i FIX-N1-102-R3 Stationary 2D-code reader, N-optics 50128782 DCR 202i FIX-M1-102-R3 Stationary 2D-code reader, M-optics 50128783 DCR 202i FIX-F1-102-R3 Stationary 2D-code reader, F-optics 50128784...
  • Page 73: Optical Accessories

    Order guide and accessories Type designation Description Part no. DCR 202i FIX-M1-102-R3-P Stationary 2D-code reader, M-optics, polarization filter 50128789 DCR 202i FIX-F1-102-R3-P Stationary 2D-code reader, F-optics, polarization filter 50128790 DCR 202i FIX-N1-102-R3-V Stationary 2D-code reader, stainless steel housing, N- 50134096...
  • Page 74: Other Accessories

    Ring light, red with 300 mm cable and M12 plug Tab. 15.10: Accessories – Mounting aids Part no. Part designation Description 50132150 BTU 320M-D12 Mounting system for 12 mm rod 50132151 BT 320M Mounting bracket 50132453 BTU 320M-D12-RL70 Mounting bracket for ring light Leuze electronic DCR 202i...
  • Page 75 KB JST-M12A-12P-50 Interconnection cable for DCR 200i to MA 2xxi modu- lar fieldbus connection Tab. 15.12: Accessories – Modular connection unit Part no. Part designation Description 50130109 MA 150 Modular connection unit for decentralized distribution of the signals in the machine Leuze electronic DCR 202i...
  • Page 76: Ec Declaration Of Conformity

    EC Declaration of Conformity EC Declaration of Conformity The code readers of the DCR 200i series have been developed and manufactured in accordance with the applicable European standards and directives. Leuze electronic DCR 202i...
  • Page 77: Appendix

    File separator GROUP SEPARATOR Group separator RECORD SEPARATOR Record separator UNIT SEPARATOR Unit separator SPACE Space EXCLAMATION POINT Exclamation point " QUOTATION MARK Quotation mark NUMBER SIGN Number sign DOLLAR SIGN Dollar sign PERCENT SIGN Percent sign Leuze electronic DCR 202i...
  • Page 78 Greater than QUESTION MARK Question mark COMMERCIAL AT Commercial AT Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Capital letter Leuze electronic DCR 202i...
  • Page 79 Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Lower case letter Leuze electronic DCR 202i...
  • Page 80: Code Samples

    DELETE (RUBOUT) Delete 17.2 Code samples Module 0.3 Fig. 17.1: Code type: 2/5 Interleaved Module 0.3 Fig. 17.2: Code type: Code 39 Module 0.3 Fig. 17.3: Code type: Codabar Module 0.3 Fig. 17.4: Code type: Code 128 Module 0.3 Fig. 17.5: Code type: EAN 128 Leuze electronic DCR 202i...
  • Page 81 SC 3 Fig. 17.7: Code type: EAN 8 SC 0                    S Fig. 17.8: Code type: EAN 13 add-on DCR 200i Fig. 17.9: Code type: DataMatrix ECC200 DCR 200i Fig. 17.10: Code type: QR Code Test symbol Fig. 17.11: Code type: Aztec DCR 200i series Fig. 17.12: Code type: PDF417 Leuze electronic DCR 202i...
  • Page 82: Configuration Via Configuration Codes

    Configuration code: reset to factory settings Setting the IP address to the Leuze default address Fig. 17.14: Configuration code: Setting the IP address DHCP activation Fig. 17.15: Configuration code: DHCP activation DHCP deactivation Fig. 17.16: Configuration code: DHCP deactivation Leuze electronic DCR 202i...
  • Page 83: License Terms

    (CD-ROM or DVD) if you submit a request to our customer support within three years of distribution of the product at the following address: Service center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Source code DCR 200i...

Table of Contents