7.2.2

Presentation mode

By reading in the following configuration code, presentation mode is set.
Figure 7.9:
Notice!
For further optional settings on this parameter, please contact Leuze electronic.
Attention!
If a trigger occurs by means of a button or trigger input while the LSIS 22x is in
presentation mode, the LSIS 22x switches to manual/serial trigger mode!
Each time the trigger button is pressed or trigger input is activated, the LSIS 22x is again
activated as long as the trigger button is pressed or a high-signal is applied at the trigger
input.
If no trigger is initiated via the button or the switching input for the duration of the hands
free time-out time (factory setting: 5s), the LSIS 22x returns to presentation mode.
In manual/serial trigger mode, the hands free time-out time is not active.
Configuring the hands free time-out time
First read in the following configuration code and then, digit by digit, the programming
codes (see "Programming codes for the configuration" on page 92) for the numerical value
of the hands free time-out time in milliseconds. Conclude parameter entry by reading in the
Save programming code.
Values can be set in the range 0 ... 300,000ms (factory setting: 5000ms) .

Figure 7.10: Configuration code for setting the hands free time-out time

Leuze electronic
Configuration code for setting the presentation mode
Technical description LSIS 22x
Configuration using configuration codes
Presentation mode
Hands free time-out
37