Cyclic Data Capacity - Renesas R-IN32 Series User Manual

Cc-link remote device station
Table of Contents

Advertisement

R-IN32 Series CC-Link Remote device station
1.4

Cyclic Data Capacity

The data amount of up to 128 bits for RX/RY and 16 words for RWr/RWw can be handled using Version 1 cyclic by
selecting the number of occupied stations (between one and four).
In addition, the data amount of up to 896 bits for RX/RY and 128 words for RWr/RWw can be handled by specifying
the extended cyclic transmission setting in Version 2.
(1) Version 1 Cyclic Data Capacity
Table 1.3 Version 1 Cyclic Data Capacity
Type
RX/RY
32 bits each
RWr/RWw
4 words each
(2) Version 2 Cyclic Data Capacity
Table 1.4 Version 2 Cyclic Data Capacity
Extended
Type
Cyclic Setting
Single
RX/RY
RWr/RWw
Double
RX/RY
RWr/RWw
Quadruple
RX/RY
RWr/RWw
Octuple
RX/RY
RWr/RWw
Remarks 1. The latter 16 bits of remote I/O (RX/RY) are reserved by the system.
2. The cyclic data capacity with an extended cyclic setting of "single" is the same as the cyclic
data capacity of Version 1.
R18UZ0056EJ0102
Dec. 28, 2018
1 Occupied Station
2 Occupied Stations
64 bits each
8 words each
1 Occupied Station
32 bits each
4 words each
32 bits each
8 words each
64 bits each
16 words each
128 bits each
32 words each
No. of Occupied Stations
3 Occupied Stations
96 bits each
12 words each
No. of Occupied Stations
2 Occupied Stations 3 Occupied Stations 4 Occupied Stations
64 bits each
96 bits each
8 words each
12 words each
96 bits each
160 bits each
16 words each
24 words each
192 bits each
320 bits each
32 words each
48 words each
384 bits each
640 bits each
64 words each
96 words each
1. Introduction
4 Occupied Stations
128 bits each
16 words each
128 bits each
16 words each
224 bits each
32 words each
448 bits each
64 words each
896 bits each
128 words each
Page 2 of 83

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-in32m4-cl2R-in32m3-ecR-in32m3-cl

Table of Contents