Table 11.3 Relationship between number of occupied stations and number of connected modules
No. of Occupied Stations
No. of connected modules of
remote device station per master
Note
Note: When the number of remote device stations connected is the same as the number of occupied
stations.
Table 11.4 Version 1 and Version 2 No. of Occupied Stations / Amt. of Cyclic Data
CC-Link Version 2
CC-Link Version 1
When the extended cyclic setting of a Version 2 system with 1 occupied station is "quadruple", the number of bit data
points handled is the same as that of a CC-Link Version 1 system with four occupied stations. When the setting is
"octuple", the amount of word data handled is the same as that of a CC-Link Version 1 system with four occupied
stations.
It is therefore possible to realize the same amount of data using a lesser number of occupied stations and, consequently,
increase the number of remote stations controlled by a single master station.
R18UZ0056EJ0102
Dec. 28, 2018
1 Station Occupied
42 modules
No. of Occupied Stations
1 occupied station, quadruple setting
1 occupied station, octuple setting
4 occupied stations
2 Stations Occupied
3 Stations Occupied
32 modules
21 modules
RX/RY: 64 bits
RWw/RWr: 16 words
RX/RY: 128 bits
RWw/RWr: 32 words
RX/RY: 128 bits
RWw/RWr: 16 words
11. Overview of CC-Link Ver. 2
4 Stations Occupied
16 modules
Amt. of Cyclic Data