Hold/Clr Register (Ccs_M3Holdclr) - Renesas R-IN32 Series User Manual

Cc-link remote device station
Table of Contents

Advertisement

R-IN32 Series CC-Link Remote device station
8.2.14

HOLD/CLR Register (CCS_M3HOLDCLR)

15
14
13
CCS_M3H
0
0
0
OLDCLR
R/W
0
0
0
Bit Position
Bit Name
0
HOLDCLR
:
Caution
The HOLD/CLR process holds or clears data received from the master station when an error,
STOP, or timeout occurs on the master station application (master station controller).
Determine the hold or clear process in accordance with device specifications, and execute the
process using firmware.
R18UZ0056EJ0102
Dec. 28, 2018
12
11
10
9
8
0
0
0
0
0
0
0
0
0
0
HOLD/CLR Information Setting
This bit notifies the master station of the HOLD or CLR setting of the HOLD/CLR
process performed by firmware.
Set the information to be notified to the master station when an error, STOP, or
time-over occurs on the master station application (master station controller), i.e.,
whether the device is to HOLD or CLR the data received from the master station.
1h: HOLD
0h: CLR
7
6
5
4
3
0
0
0
0
0
0
0
0
0
0
Function
8. Memory Map
Address
2
1
0
HOL
0
0
DCL
400F B0BA
R
0
0
R/W
Page 30 of 83
Initial
Value
0000H