Problems And Solutions; Anomalies Related To The Scope Mechanical Or Electronic - Kalor Cloe 17B User Manual

Wood pellet boiler stove
Table of Contents

Advertisement

Available languages

Available languages

Problems and solutions

All repairs must be carried out exclusively by a specialised technician, with the Hydro Insert
completely cold and the electric plug pulled out. Is prohibited from any unauthorized modifica-
tion to the device and the replacement of parts with other non-original. The operations marked
in bold type must be carried out by specialised personnel.
Check for proper combustion of the shape and color of the flame
PROBLEM
The flame thickens
at the base and the
tip has not pulled
upwards.
Flame swollen and
bursting with color
from orange to yellow
with dark tips
In normal combustion, the flame should have a tapered shape, compact, with character "lively" and with the tips tend
to be vertical or crushed towards the back of the firebox. You have to have the feeling that the flame is pulled upwards.

Anomalies related to the scope mechanical or electronic

PROBLEM
Pellet not being fed
into the combustion
chamber.
The Hydro Insert does
not run
POSSIBLE CAUSE
1. Bad regulation that
determines:
• Too full of pellets
• Low fan speed
2. The duct is obstructed or there
are pressures that hamper the
smooth evacuation of fumes
1. Combustion wrong
2. Flame oxygen deficient
POSSIBLE CAUSE
1. Pellet hopper empty
2. Feeder screw blocked by
sawdust
3. Reduction motor defective
4. Defective electronic board
5. One of the thermostats with
manual reset has tripped or the
microswitch for extraction does
not work
1. Plug out of place
2. Lack of electricity supply
3. Parameter suction power to
change
4. Pellet or water sensor in
lockout
5. Fuse blown
6. Obstruction of nests or
foreign bodies in the chimney or
fireplace
REMEDY
1. Define the adjustment of the Hydro Insert
2. Clean the smoke duct and check the pressure
switch that measures the proper depression of
the chimney
1. Define the adjustment of the Hydro Insert
2. Make sure the air duct up to the brazier is not
obstructed
3. Contact your Authorized Assistance Center
REMEDY
1. Refill pellet hopper
2. Empty the hopper and manually free the
feeder screw of sawdust
3. Replace reduction motor
4. Replace electronic board
5. Reset on the back of the Hydro Insert the safety
thermostat after verifying the cause
1. Check the correct position of the sparkplug
in the grate
2. Check that the electric socket is plugged in
and that the main switch is in position "I"
3. Contact your Authorized Assistance Center
4. Wait for the cooling of the pellets or water tank
and turn on the Hydro Insert
5. Replace the fuse
6. Remove all foreign matter from the chimney
or flue outlet of the barrel. It is recommended
that the intervention of a chimney sweep
133

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Petra 25b

Table of Contents