Sargent Profile Series v.S2 Installation Instructions Manual page 12

Wifi mortise lock
Table of Contents

Advertisement

Profile Series v.S2 WiFi Mortise Lock
Step #7 – Inside Escutcheon Wire Connections
Images are shown without gasket. If gasket is necessary,
refer to Step #5.
Before the controller is attached to the door:
1. Attach the reader assembly
ribbon cable into the back of the
controller assembly (side that
faces towards the door when
mounted (Fig. 7A).
2. Attach the antenna to the
circuit board in the plastic
housing under the
controller assembly.
Note: The difference between
the wiring for the iCLASS 13.56
MHz reader and the 125 kHz
Prox is that the iCLASS wiring
includes an antenna wire.
3. Attach the ground wire
to the bottom of the
controller assembly (E1).
Step #8 – Lock Wire Connections
1. Connect the cable from the mortise lock
to the bottom of the controller assembly
(TB1, Fig. 8A).
2. Connect the AX/DPS connector to the
2-pin harness.
3
Ground
Wire
Reader
Cable
1
Antenna
2
(iCLASS)
Outside
Escutcheon
Outside
Escutcheon
1-800-810-WIRE • www.sargentlock.com • A7786E
Reader
Ribbon Cable
1
2
Antenna
3
(iCLASS)
Ground
Wire
Fig. 7A
Reader
Ribbon Cable
1
Ground
Wire
Mortise
1
Connector
2
AX/DPS
Inside of Door
Fig. 8A
Antenna
TB1
Unused
2
Back
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents