Step #3 – Install Lockbody
To install lockbody:
1. Feed the wires first through the mortise pocket
and out the inside prep, followed by the lock-
body (Fig. 3A).
Note: Connectors and wires must be fed
through non-cylinder side.
2. The wires from the lockbody exit the inside door
prep through the mortise cutout.
3. Loosely secure the lockbody in the door with
two #12 x 1-1/4" wood screws or #12-24 x 1/2"
machine screws.
Note: Do not completely tighten at this time.
Step #4 – Door Options
A. Fire Stop Plate (P/N 52-0033)
Fire-rated doors require a fire
stop plate on the outside of the
door (Fig. 4A).
1. Drill (2) 1/8" x 1-1/4" deep holes
in the door if not already present.
Refer to template for fire-stop
prep locations.
2. Attach with flap up and
out using (2) #8 x 1/2"
self-tapping screws for
wood and metal doors.
B. Weather Conduit (52-2847)
Install weather conduit on
exterior doors only (Fig. 4B).
NON FIRE-RATED
1. Carefully insert the weather conduit into the
ribbon cable hole on the inside of the door.
2. Place the O-ring around the weather conduit
on the outside and up against the door (Fig. 4C)
(2) #12-24 x 1/2" Long
Flat Head Screws
for Metal Doors
(2) #12 x 1-1/4" Long
Flat Head Screws
for Metal Doors
Mortise
Connectors
(2) 1/8" Diameter
Holes Required
Fire Stop Plate
(2) #8 Self-Tapping
Screws for Wood
and Metal Doors
(2) Through-bolt Holes
Fig. 4A
Outside of Door
Ribbon Cable Hole
Fig.4B
1-800-810-WIRE • www.sargentlock.com • A7786E
Inside of Door
Fig. 3A
O-Ring
Fig.4C
Outside of Door
9