Intended Use Atmos ® S 201 Thorax Hose System - Atmos S 201 Thorax Operating Instructions Manual

Hide thumbs Also See for S 201 Thorax:
Table of Contents

Advertisement

Specification of the main function: Generation of a vacuum from the thoracic drainage
system through the secretion canister and hose system to the patient-sided tube end. In this
way secretion and air can be sucked through the hose system or transported into the secretion
canister. A bacterial filter in the secretion canister protects the basic device from possible
contamination with bacteria and the suction of secretion.
The vacuum which is at the patient-side is measured with the measuring- and rinsing hose.
Furthermore after a defined period a valve opens and flushes secretion, coagulum and other
blockages from the hose to the secretion canister.
User profile: Doctor, medical staff
Patient groups: Patients of all ages with and without restrictions
Application organ: Thorax
Application time: Short-term use on the patient (< 30 days).
Application site: The application site is the clinical area. The application of the device may only
be applied by healthcare professionals. The secretion canister and the drainage hose are sterile
and disposable, and can be applied in the sterile OT area.
Contraindications:
No application with other thoracic drainage systems as the ATMOS
E / S 201 Thorax.
®
No separate application of the secretion canister and the hose system (this means without basic
device) as gravity drainage.
No application under emergency conditions and in the home care field which is not supervised
by healthcare professionals.
No suction of flammable, corrosive or explosive fluids / gases.
The product is: not active
Sterility: Secretion canister is sterile.
Single-use product / reprocessing: Secretion canister is disposable.
1.2.3 Intended use ATMOS
S 201 Thorax hose system
®
Name: Hose system for the ATMOS
S / E 201 Thorax and ATMOS
C 051 Thorax
®
®
Main functions:
Transport of generated vacuum from basic device to patient-sided tube end.
Suction of secretion and air through the secretion hose into the secretion canister.
Transport of the patient-sided vacuum to the vacuum sensor for detecting the current vacuum,
which is at the patient side.
Medical indications / application:
Creating the (natural) vacuum in the pleural cavity after a pneumothorax or a pleural effusion by
draining off air and secretion.
Drainage of secretion and air after a surgical opening of the thorax.
Specification of the main function: Generation of a vacuum from the thoracic drainage
system through the secretion canister and hose system to the patient-sided tube end. In this
way secretion and air can be sucked through the hose system or transported into the secretion
canister. The vacuum which is at the patient-side is measured with the measuring- and rinsing
hose. Furthermore after a defined period a valve opens and flushes secretion, coagulum and
other blockages from the hose to the secretion canister.
User profile: Doctor, medical staff
Patient groups: Patients of all ages with and without restrictions
Application organ: Thorax
Application time: Short-term use on the patient (< 30 days).
6

Advertisement

Table of Contents
loading

Table of Contents