Step 26
(Hydraulic Hose Assembly)
Locate the hydraulic kit and the quarter turn shut off valve. Attach the hoses and shut off valve to the left side
of the infeed housing using (3) 1/2" hose "P" clamps & (3) 1/4" x 3/4" flange bolts & nuts as shown in figure
26.1. Run hose up left hand side auger tube attaching it the weld on studs using 1/2" hose "P" clamps & 1/4"
flange nuts. Leave a little slack between each stud. Run the house on the inside of the carriage mount bracket
as shown in figure 26.2.
H13XT Assembly Manual
Fig. 26.1
Fig. 26.2