Powering up and Start-up

5.3.2.1 V/f Control Type (P0202 = 0)

Seq
Indication on the Display / Action
1
Monitoring mode
Press the key ENTER/MENU to enter 1
programming mode
3
When the STARTUP group is selected press the
key ENTER/MENU
5
When the desired value is reached, press ENTER/
MENU to save the modification
Press the key
for the next parameter
7
If necessary, modify the content of "P0402 - Motor
Rated Speed"
Press the key
for the next parameter
9
To end the Start-up routine, press the Key BACK/ESC
To return to the monitoring mode, press the key
BACK/ESC again
26 | MW500
level of
st
Figure 5.4: Sequence of the Start-up group for V/f control
Seq
Indication on the Display / Action
2
The PARAM group is selected, press the keys
or
until selecting the STARTUP group
4
If necessary, press ENTER/MENU to modify the
content of "P0202 - Control Type" for P0202 = 0 (V/f)
6
If necessary, modify the content of "P0401 - Motor
Rated Current"
Press the key
for the next parameter
8
If necessary, modify the content of "P0403 - Motor
Rated Frequency"
Press the key
for the next parameter