Engine Data 16V4000M33S, Imo Tier Ii, Epa Tier - MTU 12V4000M*3 series Operating Instructions Manual

Hide thumbs Also See for 12V4000M*3 series:
Table of Contents

Advertisement

4.6 ENGINE DATA 16V4000M33S, IMO Tier II, EPA Tier 2

Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Application group
Intake air temperature
Charge-air coolant temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Rated engine speed
Continuous power ISO 3046 (10% over-
load capability, design power DIN 6280,
ISO 8528)
GENERAL CONDITIONS (for maximum power)
Intake depression (new filter)
Intake depression, max.
MODEL-RELATED DATA (basic design)
Cylinder arrangement: V angle
Bore
Stroke
Cylinder displacement
Displacement, total
Inlet valves per cylinder
Exhaust valves per cylinder
Heat exchanger
installed
3B
°C
25
°C
--
°C
25
mbar
1000
m
100
Heat exchanger
installed
A
rpm
1800
A
kW
2080
Heat exchanger
installed
A
mbar
15
L
mbar
30
Heat exchanger
installed
Degrees
90
(°)
mm
170
mm
210
Liters
4.77
Liters
76.3
2
2
MS15036/00E 2018-08 | Technical Data | 89
Heat exchanger
separate
3B
3B
45
25
--
--
32
25
1000
1000
1000
100
100
100
Heat exchanger
separate
1800
1800
1800
2080
2080
2080
Heat exchanger
separate
15
15
30
30
Heat exchanger
separate
90
90
170
170
170
210
210
210
4.77
4.77
4.77
76.3
76.3
76.3
2
2
2
2
3B
45
--
32
15
30
90
2
2

Hide quick links: