5.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑ Engine is stopped and starting disabled.
Putting into operation
Item
Lube oil system
Coolant system
Coolant system
Fuel prefilter
Engine control system
ECU
EIM
EMU
Task
Check engine oil level (→ Page 297);
Preheat engine oil if required.
Check coolant level (→ Page 313).
Preheat coolant with preheating unit.
Drain (→ Page 269);
Check that suction-side pressure indicated at the fuel prefilter pressure
gauge is within the limit (→ Page 268).
Refer to automation system operating instructions.
Check plug connections (→ Page 348).
Check plug connections (→ Page 351).
Check plug connections (→ Page 349).
MS15036/00E 2018-08 | Operation | 115