MTU 12V4000M*3 series Operating Instructions Manual page 191

Hide thumbs Also See for 12V4000M*3 series:
Table of Contents

Advertisement

311 – AL Timing Cylinder B1
Flight time measuring fault of injector
Cause
Flight time value extremely low or
extremely high.
312 – AL Timing Cylinder B2
Flight time measuring fault of injector
Cause
Flight time value extremely low or
extremely high.
313 – AL Timing Cylinder B3
Flight time measuring fault of injector
Cause
Flight time value extremely low or
extremely high.
314 – AL Timing Cylinder B4
Flight time measuring fault of injector
Cause
Flight time value extremely low or
extremely high.
315 – AL Timing Cylinder B5
Flight time measuring fault of injector
Cause
Flight time value extremely low or
extremely high.
316 – AL Timing Cylinder B6
Flight time measuring fault of injector
Cause
Flight time value extremely low or
extremely high.
ZKP-Number: 1.8004.510
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 256).
ZKP-Number: 1.8004.511
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 256).
ZKP-Number: 1.8004.512
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 256).
ZKP-Number: 1.8004.513
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 256).
ZKP-Number: 1.8004.514
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 256).
ZKP-Number: 1.8004.515
Corrective action
u Replace injector if the fault message appears frequently
(→ Page 256).
MS15036/00E 2018-08 | Troubleshooting | 189