4 Technical Data

4.1 ENGINE DATA 12V4000M33F, RheinSchUO Stage II, IMO Tier

II
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Application group
Intake air temperature
Charge-air coolant temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Rated engine speed
Continuous power ISO 3046 (10% over-
load capability, design power DIN 6280,
ISO 8528)
GENERAL CONDITIONS (for maximum power)
Intake depression (new filter)
Intake depression, max.
MODEL-RELATED DATA (basic design)
Cylinder arrangement: V angle
Bore
Stroke
74 | Technical Data | MS15036/00E 2018-08
Heat exchanger
installed
3B
°C
25
°C
°C
25
mbar
1000
m
100
Heat exchanger
installed
A
rpm
1500
A
kW
1320
Heat exchanger
installed
A
mbar
15
L
mbar
30
Heat exchanger
installed
Degrees
90
(°)
mm
170
mm
210
Heat exchanger
separate
3B
3B
32
25
-
-
-
45
25
1000
1000
100
100
Heat exchanger
separate
1500
1500
1320
1320
Heat exchanger
separate
15
15
30
30
Heat exchanger
separate
90
90
170
170
210
210
3B
32
-
45
1000
100
1500
1320
15
30
90
170
210