314 – AL Timing Cylinder B4
Cause
Time-of-flight measuring fault of
injector B4: Time-of flight
measured value extremely low or
extremely high.
315 – AL Timing Cylinder B5
Cause
Time-of-flight measuring fault of
injector B5: Time-of flight
measured value extremely low or
extremely high.
316 – AL Timing Cylinder B6
Cause
Time-of-flight measuring fault of
injector B6: Time-of flight
measured value extremely low or
extremely high.
317 – AL Timing Cylinder B7
Cause
Time-of-flight measuring fault of
injector B7: Time-of flight
measured value extremely low or
extremely high.
318 – AL Timing Cylinder B8
Cause
Time-of-flight measuring fault of
injector B8: Time-of flight
measured value extremely low or
extremely high.
146 | Troubleshooting | MS15036/00E 2018-08
ZKP-Number: 1.8004.513
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.514
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.515
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.516
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.517
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector

Hide quick links: