Engine Data 12/16V 4000 Gx3: Standby Operation 3D, Optimized Exhaust Emissions (Epa Stage 2) - MTU 12 V 4000 G23 Technical Documentation Manual

Table of Contents

Advertisement

Product Summary
2.6.3
Engine data 12/16V 4000 Gx3: Standby operation 3D, optimized
exhaust emissions (EPA stage 2)
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
Application group
Intake air temperature
Charge-air coolant temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (performance refers to net brake power as per ISO 3046)
Number of cylinders
Rated engine speed
Fuel stop power ISO 3046
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake air depression (new filter)
Intake air depression, max.
Exhaust pressure
Exhaust pressure, max.
M015710/01E 07-02
4000 G43
°C
°C
°C
mbar
m
rpm
A
A
kW
A
mbar
L
mbar
A
mbar
L
mbar
12V
12V
4000 G83
4000 G43
3D
3D
25
25
45
45
-
-
1000
1000
100
100
12
12
1800
1800
1736
1910
12
12
15
15
50
50
30
30
85
85
31
16 V
16 V
4000 G83
3D
3D
25
25
45
45
-
-
1000
1000
100
100
16
16
1800
1800
2280
2500
16
16
15
15
50
50
30
30
85
85
© MTU