POSSIBLE CAUSE
The rear board is set for a mechanical
thermostat, but the machine is
equipped with an electronic
temperature probe.
The software version (EPROM) in the
Data Link downloader in not compatible
with this equipment and will be
downloaded.
This message is a reminder that regular
maintenance may be due and will not
stop the operation of the coffee maker.
The brewer harness is not connected to
the rear board.
Overflow harness is not connected to
the rear board.
The water tank harness is not
connected to the rear board.
Indicates a problem with the main water
supply not getting to the water tank.
The "
" button has been
OPEN BREWER
pressed.
The main level probes are covered with
lime/calcium.
Product selected may be disabled.
02-2012
CORRECTIVE ACTION
Go to the "
SET TEMPERATURE
set the electronic temperature probe.
Replace the software version (EPROM)
with one that is compatible with the
Suprema model. The words "
will be printed on the EPROM decal.
The coffee maker is due for routine
maintenance.
To reset the message, enter the
and reset the service counter.
Connect the brewer harness to the rear
board.
Connect the overflow harness to the rear
board.
Connect the water tank harness to the
rear board.
At this point, the water tank is not full
and this message has to be reset. To
reset it, switch the power off and on.
If the problem persists, check all
components on the water line (water
filter, tubing, fittings, etc.).
Check inlet valve to make certain it is
functioning properly.
In the case of a temporary disruption
with the water supply, the coffee maker
will reset itself after every hour.
Pressed the "
OPEN BREWER
more to close the brewer and exit.
At this point, pressing the appropriate
buttons on the front selection panel will
reset the product counters.
The water tank may require deliming.
The main level probes need to be
cleaned/delimed.
Check the "
ENABLE SWITCHES
see if product has been canceled.
Check the price of the selection to make
certain it has not been disabled (set
below zero).