Brewer Rinse Cycle

1. Add VKI approved brewer cleaner to the brew chamber and activate the brewer
rinse cycle by pressing the "
front door.
a) Select the type of rinse cycle required. For a brewer rinse, press the "
b) The piston will now move to the top of the cylinder, water will pour in, and the
c) After the 5 minutes have elapsed, the brewer will cycle, dumping the cleaner into
d) After the rinse cycle is complete, brew a few cups of coffee to re-lubricate the
Suprema - Operation & Service
RINSE CYCLE
To cancel the rinse cycle if it was pressed accidentally, press any button (except the
"
" button) on the front selection panel. This will exit the rinse cycle and
START
return the unit to the "standby" mode.
button on the front selection panel to begin the cycle.
brewer will pause for about 5 minutes. During this time, the cleaner will break
down all the oils and stains that have accumulated on the brewer.
To cancel the five-minute pause and proceed to the seven rinse cycles, press the
"
" button. For proper brewer cleaning, it is recommended that the full cycle
START
be performed.
the waste container in the process. The brewer will then automatically cycle water
seven consecutive times to rinse the cleaner from the brewer. After the rinse cycle
is completed, the brewer will stop and the coffee maker will automatically exit the
rinse mode.
To cancel the seven rinse cycles, press the "
cleaning, it is recommended that the full cycle be performed.
brewer.
WARNING:
Make sure the waste container is under the brewer spout to
catch the water coming from the brewer (throughout the complete rinse
cycle).