4.6. Specific values for models with steam heating

4.6.1. Steam heating details

Heating power at 9 bar
(130.5 PSI)
Volume of pressurised
vessel
Steam flow rate
Nominal
Pressure
Min / Max
Steam inlet connection
Steam outlet connection

4.6.2. Electric power and consumption. Machines with steam heating

Maximum
200...240
electrical power
Total nominal
200...240
consumpt.
200...240
Maximum
electrical power
380...480
200...240
Total nominal
consumpt.
380...480
Note. This information should be supplemented with images and information from Section 4.6.
Connecting the machine
MODEL WITH STEAM HEATING
ED260
kW
19.93
(BTU/h)
(68003)
dm
3
0.5
(cu.ft)
(0.0177)
kg/h
35
bar
8
(PSI)
(116)
bar
6 / 9
(PSI)
(87/130.5)
BSP
male
1/2 in
thread
BSP
male
1/2 in
thread
MODELS WITH STEAM HEATING
VOLTAGE
(50/60Hz)
1Ph+N
kW
2Ph
1Ph+N
A
2Ph
VOLTAGE
(50/60Hz)
3Ph
kVA
3Ph
kVA
3Ph
A
3Ph
A
ED340
ED460
20.61
41.84
(70324)
(142764)
0.5
0.9
(0.0177)
(0.0318)
37
74
8
8
(116)
(116)
6 / 9
6 / 9
(87/130.5)
(87/130.5)
1/2 in
3/4 in
1/2 in
1/2 in
ED260
ED340
0.9
0.9
4.6
4.3
ED1250
2.2
2.2
6.6
3.5
ED660
ED1250
42.67
107.69
(145596)
367453
0.9
7.5
(0.0318)
(0.265)
76
194
8
10
(116)
(145)
6 / 9
6/15
(87/130.5)
(87/217.6)
3/4 in
DN32
1/2 in
DN25
ED460
ED660
1.6
1.6
7.8
8.2
Code No. 549758