CAUTION!
Check the free movement of the flap for regulating the exhaust output.
This flap is a safety device that blocks the entry of air through the exhaust pipe in the event of a blow
back.
For this reason IT SHOULD NEVER BE REMOVED.
9.2. Machines with gas heating. Analysis of the
combustion gases
Once the drying program has begun:
Wait a few minutes until the exhaust temperature exceeds
80 ºC (176 ºF).
Analyse the combustion products (Fig. 9.1). THE
RESULT MUST COMPLY WITH THE REQUIREMENTS
IN FORCE IN THE COUNTRY WHERE THE DRYER IS
INSTALLED.
Some operating conditions may call for slight modification
of the combustion control devices, particularly the Venturi.
See Section 8.2.1 on how to adjust the position of the
Venturi.