1.6. Protection, safety and control elements

 Fixed guards: Covers. These protect the user from contact with dangerous points and material accidentally
ejected from the machine.
 Mobile guards: Filter cover.
 Breaker switch: These connect or disconnect the electrical power from the machine (on some models only
in accordance with Standard EN60204-1).
 Start safety: If a momentary interruption of the power supply occurs, the machine shuts down at once and
does not resume until the corresponding start button is pressed.
 Drum access door microswitch: If the door is opened during operation, the machine switches off the
heating and halts the drum rotation.
 Filter cover microswitch: If the filter cover is opened during operation, the machine switches off the heating
and halts the drum rotation.
 Electric circuit safety measures: To protect the electric circuit against external malfunctions and prevent
any malfunctioning causing damage to the operator.
 Audible alarm: Among other functions, the alert beep warns of possible alarms.
 Drum movement detector (Reed): This detects the rotation of the drum. If rotation halts unexpectedly, the
machine switches off the heating to avoid damaging the linen.
 Input thermostat: A passive safety system that limits the input temperature. This protects against
overheating caused by a fault in the system regulating the temperature.
 Output thermostat: A passive safety system that limits the output temperature. This protects against
overheating caused by a fault in the system regulating the temperature.
 Input temperature probe and output temperature probe: These constantly monitor the temperature at the
inlet and outlet, adapting it to the programmed value.
 Pressure-switch: Controls the vacuum in the exhaust circuit.
 Safety device to prevent back-flow of fumes. Oscillating shutter that prevents air from entering through
the extraction tube in the event of a back-flow situation.
 Thermal protection for the motors: Protection against overheating of the drum drive and vacuum motors.
EMERGENCY STOP BUTTON
Safety device that halts the machine immediately and keeps it halted. This device is identified by a red button on
a yellow background located on the upper front cover.
Applying the emergency stop, depending on models
Professional control
Models ED260 and ED340. The emergency stop device is optional. (According to Standard EN60335-1, the
emergency stop device is not required in these models).
Models ED460 and ED660. The emergency stop device is installed in all the machines. (According to
Standard EN60204-1).
Coin control
Applying the emergency stop in coin-op facilities described in Chapter 6 of this manual.