Models With Breaker Switch - GIRBAU ED460 Installation Instructions Manual

Table of Contents

Advertisement

5.1.2. Models with breaker switch

Models ED260, ED340, ED460 and ED660
 Place the breaker switch handle in the OFF position.
 Remove the dryer top cover securing screws and
remove it to allow removal of the rear cover.
 Remove the upper rear cover.
 Remove the caps covering the breaker switch terminals.
 Insert the electric cable inside the dryer through the hole
(E, Fig. 4.1).
 Connect the power supply cable to the terminals of the
breaker switch (Figure 5.1). Replace the covers
protecting the terminals.
 Connect the earth cable.
 Assemble all the covers and fix them. Assemble the
switch handle.
 Check that the cable or the cable protection conduit is
correctly attached to the back cover of the machine.
Figure 5.1: Example of a connection for electrically heated machines connected to a 3Ph + N + Earth line.
Machines with gas heating
On these models, the connection is ALWAYS SINGLE-PHASE (1Ph+N) or TWO-PHASE. (2Ph). However,
they can be connected to a three-phase installation. (See the wiring diagrams in Section 4.2).
Models ED900 and ED1250 gas and steam
 Place the breaker switch handle in the OFF position.
 Remove the isolator switch cover.
 Remove the caps covering the breaker switch
terminals.
 Insert the electric cable inside the dryer through the
hole (Fig. 5.2/E).
Connecting the machine
49
Fig. 5.1
Fig. 5.2
Code No. 549758