Electrical Connection Details. Electrical Protection Devices - GIRBAU ED460 Installation Instructions Manual

Table of Contents

Advertisement

4.2. Electrical connection details. Electrical protection devices

CAUTION!
Always use copper wiring.
Neutral wire. On some models the neutral wire inside the machine is black and marked with the number
0. For further information, see the machine's wiring diagram.
The earth connection wire is identified by the initials PE/GND.
Warnings related to Sections 4.2.1 and 4.2.2
Options for connecting the machine to the mains power supply based on the electrical values set out on the
dryer's specification nameplate and the characteristics of the mains power supply to which the machine is to
be connected.
There are different connection possibilities depending on the voltage rating of the machine and the
characteristics of the mains power supply to which the machine is to be connected.
It should be stressed that:
The information in these sections should be supplemented with the images and information in Section 5.1
and the information in the machine's wiring diagram.
The box identified as Q0 in the wiring diagram shows the machine's breaker switch or connection
terminals.
Machines with electric heating:
ED*** EN: Machines with NOMINAL heating power.
ED*** ER: Machines with REDUCED heating power.
Explanation of the connection board boxes
A. Specification nameplate: values on the machine's specification nameplate.
Allows the electrical characteristics of the machine to be identified.
B.
Mains supply available (P): characteristics of the mains electricity supply where the machine is to be
connected. Voltage and number of phases.
The mains supply is identified as P in the CONNECTION DIAGRAM box.
C. Connection: Defines the characteristics of the conductor to use for connecting the machine and the value
of the external breaker switch.
Nameplate:
Heating ........................... G/V
Voltage ........................... 200...240
Phases ............................ 1Ph + N
Mains supply available (P):
Voltage ........................... 200...240
Phases ............................ 1Ph + N
Number of wires
Wire section
ED260 G
ED340 G
Automatic External Switch
Wire section
ED460 G
ED660 G
Automatic External Switch
Connecting the machine
A
B
2+PE/GND
mm
2
AWG
C
A
mm
2
AWG
A
CONNECTION DIAGRAM
1.5
14
6
1.5
14
10
31
Code No. 549758
Rev. nº 10/0418