Changing The Type Of Gas - GIRBAU ED460 Installation Instructions Manual

Table of Contents

Advertisement

5.4. Changing the type of gas

CAUTION!
THE OPERATION TO CHANGE THE TYPE OF GAS SHOULD ONLY BE CARRIED OUT BY AN
AUTHORISED TECHNICAL SERVICE (ATS).
THE COMPANY RESPONSIBLE FOR THE AUTHORISED SERVICE ACCEPTS FULL RESPONSIBILITY
FOR THE WORK CARRIED OUT AND ANY POSSIBLE CONSEQUENCES ARISING FROM IT.
ANY WORK NOT CARRIED OUT BY PERSONNEL AUTHORISED BY THE MANUFACTURER SHALL BE
CONSIDERED INADMISSIBLE AND AUTOMATICALLY LEAD TO THE LOSS OF THE MACHINE'S
WARRANTY.
THE PERSON FROM THE TECHNICAL SERVICE RESPONSIBLE FOR CHANGING THE TYPE OF GAS
MUST FILL IN THE INFORMATION ON THE SPECIFICATION NAMEPLATE CORRESPONDING TO THE
NEW TYPE OF GAS AND AFFIX IT INSTEAD OF THE
NAMEPLATE.
BEFORE CHANGING THE TYPE OF GAS, THE TECHNICIAN MUST:
READ AND ENSURE HE/SHE UNDERSTANDS CORRECTLY THE SAFETY INSTRUCTIONS SET OUT IN
THE INITIAL SECTION OF THIS MANUAL.
MAKE SURE THE SITTING OF THE MACHINE AND THE GAS INSTALLATION COMPLY WITH EXISTING
REGULATIONS CONCERNING GAS APPLIANCES FOR THE COUNTRY OR AREA WHERE THE
MACHINE IS TO BE USED.
MAKE SURE THE NEW TYPE OF GAS IS LISTED AMONG THE DIFFERENT TYPES OF GAS REFERRED
TO IN PARAGRAPH 4.3. OF THIS MANUAL. IF IN DOUBT, CONSULT THE COMPANY SUPPLYING THE
GAS.
A FLUE GAS ANALYSER MUST BE USED TO PERFORM THIS OPERATION.
For ETL certified models:
WARNING
THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE
WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION.
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION
OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
THE QUALIFIED SERVICE AGENCY IS RESPONSIBLE FOR THE PROPER INSTALLATION OF THIS KIT.
THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED
APPLIANCE IS CHECKED AS SPECIFIED IN THE MANUFACTURER'S INSTRUCTIONS SUPPLIED WITH
THE KIT.
In order to adapt the machine to a new type of gas, the following components should be requested from
the manufacturer:
Injector
Gas type change label
Deflector. In accordance to the model.
Information on the location of the details needed to fill in the label in the machine's Instruction manual.
In addition to the conventional tools (spanners and screwdrivers) the following TOOLS AND MEASURING
DEVICES are needed.
Vernier calliper
Flue gas analyser
Pressure gauge adjusted to the pressure range to be measured.
Allen key No. 4
Connecting the machine
MACHINE'S ORIGINAL SPECIFICATION
55
Code No. 549758