4.3.2. Maximum NOx values and classification

Maximum NOx values obtained and corrected in accordance with EN1020:2009:
 For 2
nd
family gases (G20 and G25): 127 mg/kWh. Class 3.
 For 3
rd
family gases (G31): 155 mg/kWh. Class 2.

4.3.3. Categories of commercially available gases

(Summary of the B1 & B4 tables taken from the EN437:2003+A1:2009 standards)
The specification nameplate identifies the type of gas prepared for the dryer.
Common to all models
COUNTRY
Austria
AT
Belgium
BE
Bulgaria
BG
Switzerland
CH
Cyprus
CY
Czech Rep.
CZ
Germany
DE
Denmark
DK
Estonia
EE
Spain
ES
Finland
FI
France
FR
U.K.
GB
Greece
GR
Hungary
HU
Ireland
IE
Iceland
IS
Italy
IT
Lithuania
LT
Luxembourg
LU
Latvia
LV
Malta
MT
Netherlands
NL
Norway
NO
Poland
PL
Portugal
PT
Romania
RO
Sweden
SE
Slovenia
YES
Slovakia
SK
Connecting the machine
NATURAL GAS
G20
I2H, II2H3P
12E+,II2E+3P
I2H, II2H3P
I2H, II2H3P
I2E
I2H
I2H
I2H, II2H3P
I2H
12H, I2E+II2H3P, II2E+3P
I2H, II2H3P
I2H, II2H3P
I2H
I2H, II2H3P
I2H, II2H3P
I2H, II2H3P
I2E
I2H
I2H
I2H
I2E
I2H, II2H3P
I2H, I2E, II2H3P
I2H
I2H, II2H3P
I2H, II2H3P
PROPANE GAS
G25
I3P, 12E+,II2E+3P
I2L, II2L3P
I3P, II2E+3P, II2H3P, II2L3P
I2L, II2L3P
I2L, II2L3P
I3P, II2H3P, II2L3P
37
G31
I3P, II2H3P
I3P, II2H3P
I3P, II2H3P
I3P
I3P, II2H3P
I3P, II2H3P
I3P, II2H3P
I3P
I3P, II2H3P
I3P, II2H3P
I3P, II2H3P
I3P, II2L3P
I3P
I3P, II2H3P
I3P, II2H3P
II2H3P