5.5. Connecting the exhaust ducting

CAUTION!
IT IS COMPULSORY FOR EXHAUST DUCTS TO BE INSTALLED BY AN REGISTERED INSTALLATION
CONTRACTOR, AND SUCH INSTALLATIONS MUST CONFORM TO THE EXISTING LAWS IN THE
COUNTRY OR AREA WHERE THE MACHINE IS USED.
DANGER!
SOOT AND LINT MUST BE PERIODICALLY CLEANED FROM THE INSIDE OF THE EXHAUST DUCTING
FROM THE MACHINE TO OUTSIDE. DO NOT FORGET THAT BOTH LINT AND SOOT ARE HIGHLY
COMBUSTIBLE MATERIALS. WE RECOMMEND CARRYING OUT THIS OPERATION AT LEAST EVERY
THREE MONTHS.
A FAULTY EXTRACTION SYSTEM CAN CAUSE SERIOUS RISKS TO THE HEALTH OF OPERATORS.
DANGER!
SPECIFIC WARNING FOR MACHINES WITH GAS HEATING.
THE EXHAUST DUCT MAY EXTRACT UNBURNT GAS.
SOME COMPONENTS FROM DRY CLEANING PROCESSES MAY DECOMPOSE INTO TOXIC AND/OR
CORROSIVE PRODUCTS IF THEY PASS THROUGH BURNER FLAMES.
FOR THIS REASON, THE MACHINE'S EXHAUST DUCT SHOULD ALWAYS LEAD DIRECTLY TO A
SECURE OUTSIDE LOCATION AND NEVER BE CONNECTED TO ANY OTHER DUCT OR CHIMNEY.
CAUTION!
SPECIFIC CAUTION FOR USA/CANADA MACHINES
CANADA: ONLY THOSE FOIL-TYPE FLEXIBLE DUCTS, IF ANY, SPECIFICALLY IDENTIFIED FOR USE
WITH THE APPLIANCE BY THE MANUFACTURER SHALL BE USED.
USA: ONLY THOSE FOIL-TYPE FLEXIBLE DUCTS, IF ANY, SPECIFICALLY IDENTIFIED FOR USE WITH
THE APPLIANCE BY THE MANUFACTURER AND THAT COMPLY WITH THE UL 2158A, SHALL BE
USED.