Code 1
Code 2
Unable to receive polling even during turn-around transmission
B0
03
due to call reservation.
B0
04
PC interface error
Communication cancelled by depressing stop key before
BF
01
confirming FAX communication.
Communication cancelled by depressing stop key after
BF
02
confirming FAX communication.
C0
01
No common modulation mode or polling failed.
C0
02
Unable to detect JM.
C0
03
Unable to detect CM.
C0
04
Unable to detect CJ.
C0
10
V. 34 negotiation or training not finished.
C0
11
Modem error detected during V. 34 negotiation or training.
C0
20
Modem error detected during sending of commands.
C0
21
Modem error detected during receiving of commands.
C0
22
Control channel connection time-out.
C0
30
Modem error detected during sending of image signals.
C0
31
Modem error detected during receiving of image signals.
E0
01
Failed to detect 1,300 Hz signal in burn-in operation.
E0
02
Failed to detect PB signals in burn-in operation.
E0
03
Command not detected from RS232C in burn-in.