APPENDIX 4. REPLACEMENT OF CONDENSER ON THE MAIN PCB
This section explains the handling method when the power fails to be turned ON due to the
condenser defective on the main PCB.
A4.1
HOW TO JUDGE CONDENSER DEFECTIVE
Judge if the failure to turn ON the power is caused by the condenser defective on the main PCB
or not with the procedures below:
(1) Unplug the power cord of the machine from the electrical outlet and leave it for 20 seconds
electrical outlet.
(2) While holding down the power switch on the control panel, plug the power cord to the electrical
outlet.
If the power is turned ON with the above operations: Condenser defective on the main PCB
If the power is not turned ON with the above operations: Other factors (power supply PCB defective
or main PCB defective, etc.)
A4.2
HOW TO REPLACE CONDENSER
Replace the condenser in accordance with the information below:
< Requirements >
- Nipper
- Soldering iron
- Solder
< Recommended solder list >
Countries
For Japan, UK,
Finland,
Germany,
France,
Sweden
For Worldwide
except
Australia,
New Zealand
For Worldwide
* For more detailed list, refer to the procedure manual on Brother Databank Information with Ref.
No. 1000049318.
Manufacturer
Origin
ALMIT
JAPAN
KESTER
U.S.A.
AIM
CANADA
App. 4-1
Name
KR-19 SH RMA
http://www.almit.com
LFM-48
KESTER245
http://www.kester.com
KESTER285
CASTIN RMA2
http://www.aimsolder.com
Web site
Confidential

Advertisement

Table of Contents
loading

Table of Contents