Instruction Manual
D103392X012
Table 3. EMC Summary Results—Emissions
Frequency
Port
Range (MHz)
30 to 230
230 to 1000
Enclosure
1000 to 3000
3000 to 6000
0.15 to 0.50
0.50 to 5
Enclosure
5 to 30
NOTES:
The 4320 is considered as a Group 1 device.
Industrial, Scientific, and Medial (ISM) radio frequency (RF) equipment is rated according to its Group and Class as follows;
Group I - Equipment in which there is intentionally generated and/or used conductively coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.
Group II - Equipment in which radio-frequency energy is intentionally generated and/or used in the form of electromagnetic radiation for the treatment of material, and EDM and arc welding
equipment.
Class A - Equipment suitable for use in industrial and commercial environments
Class B - Equipment suitable for use in domestic environments
1. Decreasing linearly with logarithm of frequency.
Table 4. Device Variables
DEVICE VARIABLE
INDEX
DD
0
Position
1
Closed Limit Switch
2
Open Limit Switch
3
Temperature
4
Supply Voltage
6
Switch States
243
Battery Life Remaining
244
PV % Range
245
Loop Current
Educational Services
For information on available courses for the 4320 wireless position monitor, as well as a variety of other products,
contact:
Emerson Process Management
Educational Services, Registration
P.O. Box 190; 301 S. 1st Ave.
Marshalltown, IA 50158-2823
Phone: 800-338-8158 or
Phone: 641-754-3771
FAX: 641-754-3431
e‐mail: education@emerson.com
Basic Standard
Group 1 Class A: 40 dB (μV/m) measured at 10 m distance
Group 1 Class B: 30 dB (μV/m) measured at 10 m distance
EN 55011
Group 1 Class A: 47 dB ( μ V/m) measured at 10 m distance
Group 1 Class B: 37 dB ( μ V/m) measured at 10 m distance
Group 1 Class B
μ
50 dB (
V/m) measured at 3 m distance, peak limit not to exceed 70 dB (
EN 55022
Group 1 Class B
μ
54 dB (
V/m) measured at 3 m distance, peak limit not to exceed 74 db (
External Power Option Only
Group 1 Class B
μ
56-46
dB (
V)
Group 1 Class B
EN 55011
μ
46
dB (
V), peak limit not to exceed 56 dB (
Group 1 Class B
μ
50 dB (
V), peak limit not to exceed 60 dB (
Gateway
PERCENT_OF_SPAN
Travel
CLOSED_TRIGGER
Reports 'Valve Closed' condition
OPEN_TRIGGER
Reports 'Valve Open' condition
DEVICE_TEMPERATURE
Electronics Module Temperature
BATTERY_VOLTAGE
Power Supply Output
SWITCH_STATE
Composite of Variables 1 and 2
BATTERY_LIFE
Estimated battery life remaining
PERCENT_RANGE
Copy of Variable 0
CURRENT
Always Indeterminate (not a number)
Emissions Level
(1)
, peak limit not to exceed 66 dB (
μ
V)
μ
V)
4320 Position Monitor
μ
V/m)
μ
V/m)
μ
V)
DESCRIPTION
(% of Calibration Output Span)
(1 = Tripped, 0 = Not Tripped)
(1 = Tripped, 0 = Not Tripped)
(Degrees C)
(Volts DC)
(0 = Partially Open, 1 = Closed, 2 = Open,
3 = Indeterminate)
(days) - meaningless with External Power option
(%)
(mA)
February 2013
Given Rating
Class A & B
Class A & B
Class A & B
Class A & B
Class A
Class A
Class A
5