Configure System Operating Parameters; Step 1: Setup Test Bench; Step 2: Login With Test Pc; Figure 17: Installation: Basic Wiring Configuration For Web/Telnet Access - Redline RDL-3000 Installation Manuallines

Universal wireless transport (uwt) system, edge wireless terminal
Hide thumbs Also See for RDL-3000:
Table of Contents

Advertisement

Edge
4.2

Configure System Operating Parameters

This section describes the basic configuration for the Edge terminal.

Figure 17: Installation: Basic Wiring Configuration for Web/Telnet Access

4.2.1

Step 1: Setup Test Bench

Connect the Edge and test PC as in the above diagram.
4.2.2

Step 2: Login with Test PC

The Edge can be configured and monitored using Telnet or a standard Web browser
(e.g., Internet Explorer 6.0 or higher). The following procedures require a PC equipped
with a Web browser, Ethernet port, and an Ethernet Cat-5e crossover cable for
connecting the PC to the PoE power adapter.
The test PC and Edge IP address must be on the same subnet. For example:
IP address = 192.168.25.5
Net Mask =
Web Browser
Use the following steps to establish a Web session with the Edge.
On the PC, open a browser and enter the unit Edge IP address in the browser
1.
address bar. The factory default IP address is 192.168.25.2.
Login to the Edge using the assigned username and password. The default
2.
username is 'admin', and the default password is 'admin'.
70-00204-01-01
INSTALLATION GUIDELINES
255.255.255.0
Proprietary Redline Communications © 2015
Page 32 of 56
May 19, 2015