Edge
3.8

Power Source

The installer must provide a compatible power source for the Edge system.
supply connections are located on the front panel of the PoE unit. This is a keyed Buchanan
796864-5 (or equiv.) connector (removable screw-type terminal block). Dual isolated floating
power supply inputs are provided to accommodate deployments with backup power (e.g., A + B
battery banks). All power inputs include overvoltage and reverse polarity protection.

Isolation

The installer must provide pluggable terminal blocks in the cabinet to isolate the PoE for
installation and servicing.

Surge Suppression

Surge suppression must be provided if the power source is external from the cabinet
(e.g., built-in to terminal blocks).
for the power cable ingress into the shelter or cabinet.

Power Requirments

The Edge system requires up to 17 W of power. The supply cable may be 12 to 22
AWG.

Cable Supports

It is important to provide strain relief, drip loops and protection against vibration and
abrasion caused by the wind, sand etc. The installer must provide suitable cable
supports for the power cable, spaced at a recommended maximum of 450 -610 mm (~18
- 24 in).
70-00204-01-01
INSTALLATION GUIDELINES

Figure 15: Site Survey: Power Wiring

: System installation must include dedicated outdoor rated surge protection
Table 10: Site Survey: Power Requirements
Power
Wire Gauge
Proprietary Redline Communications © 2015
The DC
< 17 W
12-22 AWG