All equipment must be grounded before the power cable is connected.
For electrical safety the DC power supply shall have reinforced insulation to the
mains supply.
Electrical Safety Compliance / Conformité à la Sécurité Electrique
The RDL-3000 system hardware has been tested for compliance to the electrical safety
specifications listed in the following table.
Class I
All External Circuits
All equipment must be grounded
Le RDL-3000 du matériel a été testé pour la conformité aux normes de sécurité
électriques indiquées dans le tableau suivant:
Classe I
Tous les circuits externes
Tous les équipements doivent être mis à la terre

UL Information

The suitability of the supplied Ethernet cable is subject to the approval of Authority
Having Jurisdiction and must comply with the local electrical code.
The equipment must be properly grounded according with NEC and other local
safety code and building code requirements.
Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC
which provides guidelines for proper grounding and, in particular, specifies that the
cable ground shall be connected to the grounding system of the building, as close to
the point of cable entry as is practical.
RDL-3000 system must be installed in compliance with relevant articles in National
Electrical Code-NEC (and equivalent Canadian Code-CEC) including referenced
articles 725, 800 and 810 in NEC.
RF coaxial cable connecting an antenna to the RDL-3000 system must comply with
the local electrical code.
To meet the over-voltage safety requirements on the telecommunications cables, a
minimum 26 AWG telecommunication line cord must be used.
Pour être en conformance avec les exigences finies de sûreté de sur-tension sur les
câbles de télécommunications un fil de télécommunication ayant un calibre minimum
de 26 AWG doit être utilisé.

Lightning Protection / Protection Contre la Foudre

When installed, this equipment is to be connected to a Lightning/Surge Protection
Device that meets all applicable national safety requirements. Before Ethernet cables
enter buildings, voltages shall be clamped down to SELV by approved type primary
protectors.
WARNING: The information provide in this user manual consists of general
recommendations for installation the system equipment. The wireless equipment must
be installed by a qualified professional installer who is knowledgeable of the
requirements of installing outdoor radio equipment and follows local and national codes
70-00204-01-01
INSTALLATION GUIDELINES

Table 1: Notice: Electrical Safety Specifications

Table 2: Avis: Spécifications de sécurité électrique
Proprietary Redline Communications © 2015
EN 60950-1
TNV-1 as defined in EN 60950-1
EN 60950-1
TRT-1 tel que défini dans la norme EN
60950-1