Install Outdoor Equipment; Step 1: Assemble Ethernet And Rf Port Connections; Assemble Ethernet Port Connection; Figure 20: Installation: Ethernet Port Gland Assembly - Redline RDL-3000 Installation Manuallines

Universal wireless transport (uwt) system, edge wireless terminal
Hide thumbs Also See for RDL-3000:
Table of Contents

Advertisement

Edge
4.3

Install Outdoor Equipment

4.3.1

Step 1: Assemble Ethernet and RF Port Connections

Assemble Ethernet Port Connection

The Redline outdoor Ethernet cable is terminated with a non-hooded RJ-45 connector.
This connects to the metal RJ-45 connector located on the wireless terminal enclosure.
When connecting the outdoor Ethernet cable to the wireless terminal, ensure the RJ-45
plug is fully inserted and locked into the socket. Test the locking function by applying a
very light pulling pressure (two fingers) on the cable.
The Ethernet port is protected by a weatherproof gland. The Ethernet cable must be
threaded through the connector components and the connector and re-assembled. The
Ethernet
weatherproofing must be applied (see following pages).
Use the following steps to connect the Ethernet cable. The connector assembly is
provided as a separate item in the shipping container.
1. Remove the connector from the packaging and arrange the individual components in
the order displayed in the diagram.
2. Insert the Ethernet cable through the sealing nut (4), seal (3), body (2) and gasket
(1).
3. Connect the Ethernet cable connector to the RJ-45 socket. Inserting the RJ-45 plug
into the socket should produce an audible 'click' from the locking mechanism.
4. Position the gasket (1) against the Ethernet port.
5. Thread the body (2) onto the Ethernet port. The body must be finger-tight plus 1/2
turn, or approximately 47 N-m (35 ft-lb).
6. Two sizes of split seals (3) are provided to accommodate single and double shielded
cables. Choose the seal that fits tightly on the cable without distorting. Slide the split
seal along the Ethernet cable until it is tight against the body (2).
7. Thread the sealing nut (4) on to the body. The sealing nut must be finger-tight plus
1/2 turn. This is approximately 47 N-m (35 ft-lb).
8. Weatherproof the Ethernet port (see instructions on following page).
70-00204-01-01
INSTALLATION GUIDELINES
port
seal
is
water-resistant

Figure 20: Installation: Ethernet Port Gland Assembly

Proprietary Redline Communications © 2015
when
assembled
correctly.
Page 36 of 56