4.4

Configure System Operating Parameters

Use the following steps to setup a basic link between the base station and the Connect-
OW wireless terminal:
Install the Connect system.
1.
Use an Ethernet jumper cable to connect the test PC to the Connect system.
2.
Power-on the Connect system and login to the management interface (Web or CLI).
3.
If additional features have been purchased, enter the new options key.
4.
Configure the Connect network and wireless settings.
5.
4.4.1

Required Materials

Configuration of the Connect system settings requires additional equipment and
materials supplied by the installer. The following list is a guideline only, and additional
materials may be required based on local conditions at each installation site.
#
Item
1
Cabinet
2
Ethernet Cable
4.4.2

Establish Communications with Test PC

The wireless terminal can be configured and monitored using standard Web browser
(e.g., Firefox or Internet Explorer) or a Telnet client.

Figure 42: Configuration: Connect-OW System Configuration Using PC

The TCP/IP address of the PC must be on the same subnet as the wireless terminal.
For example, set the PC address as follows:
TCP/IP address =
Net Mask =
70-00200-01-00
Installation Guidelines

Table 16: Installation: Installer Supplied Materials

Description
Portable computer with Web browser and/or Telnet client.
crossover
A CAT-5e
192.168.25.5
255.255.255.0
Proprietary Redline Communications © 2014
cable terminated with RJ-45 at both ends.